3. Select the EP-15 Fluid Level and press ENT.<br />

4. Press ↓ to select CALIBRATE and press ENT. The Device Calibration<br />

menu will appear. Instructions on Calibration will be listed at the top<br />

of the menu.<br />

5. Highlight NUM PTS, press ENT and select 2. Press ENT.<br />

6. Select FLUID LEVEL, press ENT, then select EMPTY LEVEL and press ENT.<br />

7. Make sure the fuel tank is empty, highlight CALIBRATE and press ENT.<br />

The following message will appear: Empty Level Calibration Completed.<br />

Press ENT.<br />

8. Fill up your tank, highlight FLUID LEVEL and press ENT.<br />

9. Select FULL LEVEL and press ENT. Highlight CALIBRATE and press ENT.<br />

10. The following message will appear: Full level Calibration Completed.<br />

Press ENT, then press EXIT repeatedly to get back to the main<br />

display.<br />

Calibrate is highlighted on the device configuration menu (left). Calibration<br />

menu (right) with calibration instructions listed at the top.<br />

3-Point Calibration<br />

3-point calibration is designed for tanks that vary in shape from the top<br />

to the bottom. You can begin calibration at any point in the 3-point<br />

process, but we recommend starting calibration with an empty tank.<br />

In a 3-point calibration, you will set three points, one each for empty,<br />

half and full levels.<br />

1. Press MENU| MENU, use ↓ ↑ to select NMEA 2000 and press ENT.<br />

2. Highlight BUS SETUP and press ENT, which will open the Bus Configuration<br />

menu. A list of network devices will be at the top of the page. 3.<br />

Select the EP-15 Fluid Level and press ENT.<br />

107