<strong>CCOS</strong> Field Operations Plan Version 2: 5/31/00<br />

Table 4.5-1. Summary of Meteorolgy Audit Methods and Criteria.<br />

Measurement<br />

Variable<br />

Audit Criteria<br />

Procedure<br />

Reference<br />

General Procedure<br />

Horizontal<br />

Speed<br />

Wind<br />

Accuracy ±(0.2 m/s + 5% of<br />

observed)<br />

Equivalent wind speed<br />

starting torque to meet the<br />

wind speed starting thresholds<br />

for the respective sensors.<br />

EPA-454/R-99-005-013<br />

with 3/15/99 updates<br />

EPA/600/R-94-038d<br />

Three wind speeds within the expected range of operation. If any points are<br />

outside of criteria then corrective action is necessary.<br />

Horizontal<br />

Direction<br />

Wind<br />

Accuracy ±3 degrees for<br />

linearity, ±2 degrees for<br />

alignment to known direction.<br />

Equivalent wind speed<br />

starting torque to meet the<br />

wind speed starting thresholds<br />

for the respective sensors.<br />

EPA-454/R-99-005-013<br />

with 3/15/99 updates<br />

EPA/600/R-94-038d<br />

Depending on the mechanical sensor type from 4 to 36 points equally spaced<br />

around the compass will be compared. If any points are outside of criteria<br />

then corrective action is necessary. Torque measurements will be made to<br />

determine the mechanical sensor starting threshold. Sensor alignment will be<br />

verified using solar methods.<br />

Temperature ±0.5°C EPA-454/R-99-005-013<br />

with 3/15/99 updates<br />

Three temperatures within the expected range of temperatures (0 to 40°C). If<br />

any points are outside of criteria then corrective action is necessary.<br />

EPA/600/R-94-038d<br />

Solar Radiation ± 5% of observed EPA-454/R-99-005-013<br />

with 3/15/99 updates<br />

EPA/600/R-94-038d<br />

Barometric Pressure ±3 mb EPA-454/R-99-005-013<br />

with 3/15/99 updates<br />

Five measurements within the range of operations on a given audit day will<br />

be made. If any points are outside of criteria then corrective action is<br />

necessary.<br />

Three pressures over the period of the audit will be compared. If any points<br />

are outside of criteria then corrective action is necessary.<br />

EPA/600/R-94-038d<br />

Relative Humidity ± 1.5°C equivalent dew point EPA-454/R-99-005-013<br />

with 3/15/99 updates<br />

EPA/600/R-94-038d<br />

Three comparisons are made of the station sensor to an aspirated<br />

psychrometer. If any points are outside of criteria then corrective action is<br />

necessary. An alternate method is to use LiCl salt solutions for a direct<br />

evaluation of the response at know relative humidities. This method is<br />

preferred for the high accuracy systems since solutions can be selected at the<br />

Chapter 4: QUALITY ASSURANCE 4-24