<strong>CCOS</strong> Field Operations Plan Version 2: 5/31/00<br />
Table 4.5-1. Summary of Meteorolgy Audit Methods and Criteria.<br />
Measurement<br />
Variable<br />
Audit Criteria<br />
Procedure<br />
Reference<br />
General Procedure<br />
Horizontal<br />
Speed<br />
Wind<br />
Accuracy ±(0.2 m/s + 5% of<br />
observed)<br />
Equivalent wind speed<br />
starting torque to meet the<br />
wind speed starting thresholds<br />
for the respective sensors.<br />
EPA-454/R-99-005-013<br />
with 3/15/99 updates<br />
EPA/600/R-94-038d<br />
Three wind speeds within the expected range of operation. If any points are<br />
outside of criteria then corrective action is necessary.<br />
Horizontal<br />
Direction<br />
Wind<br />
Accuracy ±3 degrees for<br />
linearity, ±2 degrees for<br />
alignment to known direction.<br />
Equivalent wind speed<br />
starting torque to meet the<br />
wind speed starting thresholds<br />
for the respective sensors.<br />
EPA-454/R-99-005-013<br />
with 3/15/99 updates<br />
EPA/600/R-94-038d<br />
Depending on the mechanical sensor type from 4 to 36 points equally spaced<br />
around the compass will be compared. If any points are outside of criteria<br />
then corrective action is necessary. Torque measurements will be made to<br />
determine the mechanical sensor starting threshold. Sensor alignment will be<br />
verified using solar methods.<br />
Temperature ±0.5°C EPA-454/R-99-005-013<br />
with 3/15/99 updates<br />
Three temperatures within the expected range of temperatures (0 to 40°C). If<br />
any points are outside of criteria then corrective action is necessary.<br />
EPA/600/R-94-038d<br />
Solar Radiation ± 5% of observed EPA-454/R-99-005-013<br />
with 3/15/99 updates<br />
EPA/600/R-94-038d<br />
Barometric Pressure ±3 mb EPA-454/R-99-005-013<br />
with 3/15/99 updates<br />
Five measurements within the range of operations on a given audit day will<br />
be made. If any points are outside of criteria then corrective action is<br />
necessary.<br />
Three pressures over the period of the audit will be compared. If any points<br />
are outside of criteria then corrective action is necessary.<br />
EPA/600/R-94-038d<br />
Relative Humidity ± 1.5°C equivalent dew point EPA-454/R-99-005-013<br />
with 3/15/99 updates<br />
EPA/600/R-94-038d<br />
Three comparisons are made of the station sensor to an aspirated<br />
psychrometer. If any points are outside of criteria then corrective action is<br />
necessary. An alternate method is to use LiCl salt solutions for a direct<br />
evaluation of the response at know relative humidities. This method is<br />
preferred for the high accuracy systems since solutions can be selected at the<br />
Chapter 4: QUALITY ASSURANCE 4-24