Parlier Existing Equipment:<br />

Observable<br />

Instrument<br />

<strong>Ozone</strong> Dasibi Model 1008-H<br />

NO x TECO Model 42<br />

Methane, NMHC<br />

TECO Model 55c<br />

Gas Calibration Dasibi Model 5008<br />

Data Logger ETC 6002<br />

HC<br />

Canister Samples<br />

Meteorology (WD,WS,T,RH,P,SR)<br />

10 m Tower<br />

Parlier Supplemental Equipment:<br />

Observable Instrument Installer<br />

NOY/NO Y * by TEI 42C TL with 2 external converters and DRI (Bowen)<br />

chemiluminescence<br />

HNO 3 denuder<br />

NO 2 /PAcN by chemiluminescence<br />

and luminol<br />

CE-CERT<br />

DRI (Bowen)/CE-CERT<br />

(Fitz)<br />

PM 2.5 nitrate by flash volatilization R&P DRI (Bowen)<br />

CO by infrared gas filter<br />

TEI 48C TL<br />

DRI (Bowen)<br />

correlation<br />

CO 2 by infrared gas filter<br />

TEI 41C HL<br />

DRI (Bowen)<br />

correlation<br />

C 8 - C 20 HC from TENAX DRI Multi-Channel Sequential TENAX DRI (Zielinska)<br />

Sampler<br />

Gas Chromatography - Mass Varian 3800 GC + Varian 2000 MS + DRI (Sagebiel)<br />

Spectrometry<br />

ENTECH 7100 Pre-Concentrator<br />

HCHO (Formaldehyde) by<br />

Alpha-Omega MA100<br />

CE-CERT (Fitz)<br />

methanalyzer<br />

Light absorption by aethalometer Andersen RTAA-1000 (Magee Scientific DRI (Bowen)<br />

AE31)<br />

Light scattering by nephelometer Radiance <strong>Research</strong> M903 DRI (Bowen)<br />

Actinic flux by spectral Metcon 2-pi diode array spectometer DRI (Stockwell)<br />

radiometer<br />

Data Logger PC DRI(Bowen)<br />

TDLAS<br />

CE-CERT<br />

New Facilities:<br />

10’ x 32’ trailer, power, 1 phone line (DRI), 1 DSL line (DRI)<br />

Installer: ENSR (McDade)<br />

Summary of Responsibilities:<br />

Equipment Installation<br />

Calibrations<br />

Local Site Operations<br />

Technical Support<br />

VOC Sample Collection<br />

VOC Sample Analysis<br />

Data Acquisition<br />

Level 0 Data Validation/Reporting<br />

DRI(Bowen,Sagebiel,Stockwell)/CE-CERT<br />

(Fitz)/AtmAA(Fung)<br />

DRI<br />

SJVUAPCD(Nelson)DRI(McDaniel),CE-CERT<br />

DRI<br />

SJVUAPCD(Nelson)<br />

DRI(Tenax Cartridges)/ARB(HC<br />

Canisters)/ARB(Carbonyls)<br />

DRI<br />

DRI<br />

D-48