11.07.2014 Views

Central California Ozone Study (CCOS) - Desert Research Institute

Central California Ozone Study (CCOS) - Desert Research Institute

Central California Ozone Study (CCOS) - Desert Research Institute

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Existing Monitoring Equipment (vendor/model if available): This is an existing meteorological site operated by<br />

BAAQMD, with sensors on a 10m tower. Otherwise, all equipment is new (supplemental) equipment. See below.<br />

Sunol Supplemental Equipment:<br />

Observable Instrument Installer<br />

O 3 by ultraviolet absorption API 400 A DRI (Bowen)<br />

NOY/NO Y * by chemiluminescence TEI 42C TL with 2 external converters and HNO 3 DRI (Bowen)<br />

denuder<br />

NO/NO x by chemiluminescence TEI 42C TL DRI (Bowen)<br />

NO 2 /PAcN by chemiluminescence and luminol CE-CERT DRI<br />

(Bowen)/CE-<br />

CERT (Fitz)<br />

PM 2.5 nitrate by flash volatilization R&P DRI (Bowen)<br />

CO by infrared gas filter correlation TEI 48C TL DRI (Bowen)<br />

CO 2 by infrared gas filter correlation TEI 41C HL DRI (Bowen)<br />

C 2 - C 12 HC from canisters DRI Multi-Channel Sequential HC Sampler DRI (Zielinska)<br />

C 8 - C 20 HC from TENAX DRI Multi-Channel Sequential TENAX Sampler DRI (Zielinska)<br />

Gas Chromatography - Mass Spectrometry Varian 3800 GC + Varian 2000 MS + ENTECH DRI (Sagebiel)<br />

7100 Pre-Concentrator<br />

HCHO (Formaldehyde) by methanalyzer Alpha-Omega MA100 CE-CERT (Fitz)<br />

C 1 - C 7 carbonyls from DNPH<br />

AtmAA (Fung)<br />

Light absorption by aethalometer Andersen RTAA-1000 (Magee Scientific AE31) DRI (Bowen)<br />

Light scattering by nephelometer Radiance <strong>Research</strong> M903 DRI (Bowen)<br />

Actinic flux by spectral radiometer Metcon 2-pi diode array spectometer DRI (Stockwell)<br />

New Facilities:<br />

8’ X 10’ shelter, power, 1 phone line, 1 DSL line<br />

Installer: ENSR (McDade)<br />

.<br />

Summary of Responsibilities:<br />

Equipment Installation<br />

Calibrations<br />

Local Site Operations<br />

Technical Support<br />

VOC Sample Collection<br />

VOC Sample Analysis<br />

Data Acquisition<br />

Level 0 Data Validation/Reporting<br />

DRI(Bowen,Sagebiel,Zielinska,Stockwell),CE-<br />

CERT(Fitz), AtmAA(Fung)<br />

DRI<br />

UCB(Martien), DRI(Sagebiel, during IOPS)<br />

UCB<br />

UCB<br />

DRI(HC canisters, Tenax Cartridges),<br />

AtmAA(carbonyls)<br />

DRI (Bowen)<br />

DRI (Bowen)<br />

D-44

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!