Viewing Measurement Results<br />

Measured Values<br />

Click the Measured tab to display the measured values.<br />

Relative Values<br />

If Relative to Reference testing is enabled, you can display the calculated relative<br />

values by clicking the Relative tab (see Taking Measurements Relative to a<br />

Reference on page 3 -60).<br />

Reference Values<br />

If Relative to Reference testing is enabled, you can display the reference values<br />

by clicking the Reference tab (see Creating a Custom Reference File on<br />

page 3 -62).<br />

Limit Values<br />

If Limit testing is enabled (see Taking Measurements with Limit Testing on<br />

page 3 -64), you can display the Limit values by clicking the Limits tab. The<br />

minimum and maximum values are set in the limits file for the supported<br />

combination of resolution, refresh rate, and timing standard. Select the min<br />

option to display the minimum limit values for the measurement. Select the max<br />

option to display the maximum limit values for the measurement. Refer to<br />

Figure 3 -48.<br />

Figure 3- 48: Limit values for the H Sync Jitter measurement<br />

Additional Units<br />

The only additional unit available in the Results window for the H Sync Jitter<br />

measurement is % in the Measured tab and the Relative tab.<br />

3- 120 VM5000 Automatic Video Measurement Set <strong>User</strong> <strong>Manual</strong>