Appendix B: Performance Verification<br />

Table B -10 uses the values of DC700 DC0 from the example Table B -9 on<br />

page B -23.<br />

Table B- 10: Example of Amplitude measurement results<br />

Characteristic G B R<br />

Measured White level 699.0 mV 696.2 mV 698.3 mV<br />

Measured Black level 0.0 mV -1.7 mV -0.5 mV<br />

Measured White-to-Black<br />

Amplitude (MWL -MBL)<br />

699.0 mV 697.9 mV 698.8 mV<br />

Lower White limit value<br />

Upper White limit value<br />

Lower Black limit value<br />

Upper Black limit value<br />

Lower White-to-Black limit<br />

value<br />

Upper White-to-Black limit<br />

value<br />

{(700.1 mV) x (0.980)} - 8 mV = 678.1 mV<br />

{(700.1 mV) x (1.020)} + 8 mV = 722.1 mV<br />

(0.0mV)-(8mV)=-8.0mV<br />

(0.0 mV) + (8 mV) = +8.0 mV<br />

{[(700.1 mV) x (0.0 mV)] x (0.982)} - (3 mV) = 684.5 mV<br />

{[(700.1 mV) x (0.0 mV)] x (1.018)} + (3 mV) = 715.7 mV<br />

In this example, all three channels meet their White, Black, and White-to-Black<br />

specifications.<br />

Check Noise Floor<br />

Measurement Accuracy<br />

This test verifies the noise floor of the three VM5000 channels (CH1/G, CH2/B,<br />

CH3/R) and digitizers. Noise floor affects the linearity of the noise measurement<br />

between -56 dB and -32 dB.<br />

Required<br />

equipment<br />

Prerequisites<br />

A standard PC<br />

VGA to 5 BNC cable<br />

75 Ω precision BNC terminations (3)<br />

The VM5000 (including MIU) must warm up for at least 20 minutes<br />

before doing this test.<br />

1. If the VM5000 Option VGA application is not already running, start it now:<br />

from the Tekscope menu bar, select File > Run Application > VM5000<br />

VGA Video.<br />

2. In the VM5000 application, select the default setup: from the VM5000 menu<br />

bar, select File > Recall Default Setup.<br />

B-24 VM5000 Automatic Video Measurement Set <strong>User</strong> <strong>Manual</strong>