3.17. How to copy the products from iris server into pen-drive<br />

Mount the pen drive as per the procedure indicared in 3.1 followed by command:<br />

[root@DELHI-WS ~]# cp -rf /home/operator/Desktop/<br />

3.18. How to copy the error log files from rcp8<br />

After getting connected to RCP8 using ssh command, use the following commands.<br />

[operator@DELHI-RCP8]$ cd /usr/iris_data/log<br />

[operator@DELHI-RCP8]$ ls<br />

Listing of log files is displayed. the following copy command is to be given for getting secured<br />

copy of ERROR files into the Desktop folder of the internet computer.<br />

[operator@DELHI-RCP8]$ scp–r /usr/iris_data/log/IRIS_ERROR.LOG internet:<br />

/home/operator/Desktop<br />

3.19. Responsibilities of station in-charge<br />

1 Overall supervision of DWR station.<br />

2 To ensure discipline, punctuality and performance at station. To optimize output from<br />

staff, efficiently manage the available staff in view of severe shortage of staff faced by the<br />

office. He may devise new schemes, rosters, methodologies, and adaptive roles to be<br />

played by officers of various cadres to manage efficiently the operation and maintenance<br />

of radar. He should ensure that proper log books are maintained at the station.<br />

3 To repair minor problems of radar within 2 hours and to report to radar lab in O/o<br />

DDGM(UI) or any other nodal office assigned by them to be responsible for providing<br />

technical support for WSR-98D/S radars.<br />

4 If the Time Of Restoration (TOR), hereafter called as TOR, is expected to be beyond 2<br />

hours, message is to be displayed in the IMD website that radar is under maintenance.<br />

5 To seek the help of other DWR Stations and H.Q in case of difficulty in radar maintenance<br />

due to severity of the problem or non-availability of spares.<br />

6. To prepare various flow charts at block-diagram level for various signal paths like servo<br />

control, Video Generation, various interlocks, etc., using technical manuals and personal<br />

observation of wiring during maintenance. This greatly enhances the speed of servicing<br />

and also helps a newly posted staff members at the station.<br />

7. To liaise with various forecasting offices to increase the utility of DWR Products.<br />

8. To conduct seminars/workshops in order to enhance the working knowledge of staff at the<br />

station and to impart training to forecasters in understanding DWR Products.<br />