SA9-3<br />
position 3 of A1SA9.<br />
No. Position Parameter<br />
8 A1P5/<br />
SA9-4<br />
Table C.2. Location and Calibration of panel meters<br />
Calibration method<br />
+28 VDC Adjust A1A2R30 to make the reading of A1P5 equal to 28 volts at<br />
position 4 of A1SA9.<br />
9 A1P5/<br />
SA9-5<br />
10 A1P5/<br />
SA9-6<br />
+40 VDC Adjust A1A2R31 to make the reading of A1P5 equal to 40 volts at<br />
position 5 of A1SA9.<br />
+510 VDC Adjust A1A2R23 to make the reading of A1P5 equal to 510 volts at<br />
position 6 of A1SA9.<br />
11 A1P5/<br />
SA9-7<br />
12 A1P5/<br />
SA9-8<br />
13 A1P5/<br />
SA9-9<br />
14 A1P5/<br />
SA9-10<br />
15 A1P5/<br />
SA9-11<br />
16 A1P5/<br />
SA9-12<br />
Filament<br />
Power<br />
Supply<br />
Inverse<br />
Voltage<br />
Filament<br />
Voltage<br />
Focus Coil<br />
Voltage<br />
Ion Pump<br />
Voltage<br />
Beam<br />
Current<br />
Electron-<br />
Beam<br />
voltage<br />
Measure the peak-to-peak voltage between terminals 1 and 2 of the<br />
terminal board A7A1XT1 using an oscilloscope and read the value.<br />
Adjust A1A2R24 to make the reading of A1P5 equal to the value at<br />
position 7 of A1SA9<br />
Adjust A1A2R32 to make the reading of A1P5 equal to the nameplate<br />
filament voltage value of klystron V1 at position 8 of A1SA9.<br />
Measure the voltage value between terminals 1 and 2 of the terminal<br />
board L1XT1 using a multi-meter. Adjust A1A2R25 to make the<br />
reading of A1P5 equal to the value at position 9 of A1SA9<br />
Adjust A1A2R26 to make the reading of A1P5 equal to 3KV at position<br />
10 of A1SA9.<br />
Adjust A1A2R19 to make the reading of the A1P5 equal to 24<br />
milliamperes at position 11 of A1SA9 with the PRF 322Hz and narrow<br />
pulse.<br />
Adjust A1A2R16 and A1A2R16B to make the reading of A1P5 equal to<br />
60KV at position 12 of A1SA9.<br />
17 A1P5/<br />
SA9-13<br />
Inverse Peak Adjust A1A2R18 to make the reading of the A1P5 equal to 11<br />
Current milliamperes at position 13 of A1SA9 with the PRF 322Hz and narrow<br />
pulse.<br />
18 A1P5/<br />
SA9-14<br />
Charge<br />
Current<br />
Adjust A1A2R17 to make the reading of A1P5 equal to 0.65 amperes at<br />
position 14 of A1SA9 with the PRF 322Hz and narrow pulse.<br />
19 A1P5/ Regulating Adjust A1A2R11 to make the reading of A1P5 equal to 5 milliamperes<br />
74