4. Observe that the PFN voltage goes to zero, focus coil current goes to zero and high<br />
voltage goes off.<br />
5. Observe that the waveguide arc indicator is illuminated at the fault display panel.<br />
6. Observe that the FAULT and MANUAL RESET indicators at the cabinet top are<br />
illuminated.<br />
7. Press MANUAL RESET switch and FAULT DISPLAY RESET switch.<br />
8. Observe that the three indicators listed in step No.5 goes off.<br />
9. Press the LOCAL/REMOTE CTRL switch on the Tx Control panel so that the remote<br />
control indicator lights up. Restore the system to normal operation by performing the RDA<br />
power-on procedures given in 6.5.3 of manual 510.<br />
79