24.10.2014 Views

Doppler Weather Radar - METNET - India Meteorological Department

Doppler Weather Radar - METNET - India Meteorological Department

Doppler Weather Radar - METNET - India Meteorological Department

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4. Observe that the PFN voltage goes to zero, focus coil current goes to zero and high<br />

voltage goes off.<br />

5. Observe that the waveguide arc indicator is illuminated at the fault display panel.<br />

6. Observe that the FAULT and MANUAL RESET indicators at the cabinet top are<br />

illuminated.<br />

7. Press MANUAL RESET switch and FAULT DISPLAY RESET switch.<br />

8. Observe that the three indicators listed in step No.5 goes off.<br />

9. Press the LOCAL/REMOTE CTRL switch on the Tx Control panel so that the remote<br />

control indicator lights up. Restore the system to normal operation by performing the RDA<br />

power-on procedures given in 6.5.3 of manual 510.<br />

79

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!