FAILURE<br />
Drive motor runs, but<br />
dryer does not heat.<br />
(gas dryer)<br />
CHECK<br />
1. Is the gas turned on?<br />
2. Disconnects power from the dryer,<br />
raise the main top, reconnect power,<br />
set the fabric selector switch to high<br />
<strong>and</strong> start the dryer. Measure the<br />
voltage drop between terminal 5 (the<br />
terminal with the blue wire on it) of<br />
the fabric selector switch <strong>and</strong> neutral.<br />
3. Disconnect power <strong>and</strong> remove the<br />
accumulator. Masure the resistance<br />
between the terminals of switch B.<br />
4. Disconnect power from the dryer,<br />
turn the gas off to the dryer,<br />
disconnect the belt from the motor,<br />
<strong>and</strong> remove the front panel. Set the<br />
fabric selector switch to high <strong>and</strong><br />
observe the igniter for one minute.<br />
5. Measure the voltage drop from the<br />
terminal on the sensor with orange<br />
wire to neutral.<br />
6. Remove power, unplug the igniter <strong>and</strong><br />
measure the resistance of the igniter.<br />
Yes, go to step 2.<br />
No, turn the gas on.<br />
CORRECTION<br />
If the meter read zero, go to step 3<br />
If the meter reads line to neutral, go to step.<br />
4.<br />
If the meter read zero, the control thermostat<br />
defective.<br />
If the meter reads infinity, switch B is<br />
defective.<br />
If the igniter glows full brilliance or glows dim,<br />
the full minute, defective sensor.<br />
If the igniter close full brilliance then dims,<br />
defective gas valve or gas supply.<br />
If the igniter does not glow, go to step 5.<br />
If the meter reads zero, defective safety<br />
thermostat.<br />
If the meter reads line to neutral voltage, go<br />
to step 6.<br />
If the meter reads infinity, they igniter is<br />
defective.<br />
If the meter reads between 50 <strong>and</strong> 400 ohms,<br />
the drive motor is defective.<br />
Note:<br />
Always check for defective wiring between the <strong>com</strong>ponents before condemning any <strong>com</strong>ponent.<br />