FAILURE<br />

Drive motor runs, but<br />

dryer does not heat.<br />

(gas dryer)<br />

CHECK<br />

1. Is the gas turned on?<br />

2. Disconnects power from the dryer,<br />

raise the main top, reconnect power,<br />

set the fabric selector switch to high<br />

<strong>and</strong> start the dryer. Measure the<br />

voltage drop between terminal 5 (the<br />

terminal with the blue wire on it) of<br />

the fabric selector switch <strong>and</strong> neutral.<br />

3. Disconnect power <strong>and</strong> remove the<br />

accumulator. Masure the resistance<br />

between the terminals of switch B.<br />

4. Disconnect power from the dryer,<br />

turn the gas off to the dryer,<br />

disconnect the belt from the motor,<br />

<strong>and</strong> remove the front panel. Set the<br />

fabric selector switch to high <strong>and</strong><br />

observe the igniter for one minute.<br />

5. Measure the voltage drop from the<br />

terminal on the sensor with orange<br />

wire to neutral.<br />

6. Remove power, unplug the igniter <strong>and</strong><br />

measure the resistance of the igniter.<br />

Yes, go to step 2.<br />

No, turn the gas on.<br />

CORRECTION<br />

If the meter read zero, go to step 3<br />

If the meter reads line to neutral, go to step.<br />

4.<br />

If the meter read zero, the control thermostat<br />

defective.<br />

If the meter reads infinity, switch B is<br />

defective.<br />

If the igniter glows full brilliance or glows dim,<br />

the full minute, defective sensor.<br />

If the igniter close full brilliance then dims,<br />

defective gas valve or gas supply.<br />

If the igniter does not glow, go to step 5.<br />

If the meter reads zero, defective safety<br />

thermostat.<br />

If the meter reads line to neutral voltage, go<br />

to step 6.<br />

If the meter reads infinity, they igniter is<br />

defective.<br />

If the meter reads between 50 <strong>and</strong> 400 ohms,<br />

the drive motor is defective.<br />

Note:<br />

Always check for defective wiring between the <strong>com</strong>ponents before condemning any <strong>com</strong>ponent.<br />