9.8 Bus System<br />

Option Pakscan [OP]<br />

Pakscan Address<br />

PA Pb Pakscan<br />

Baud Rate<br />

43<br />

Setting instructions for actuators<br />

including an optional Pakscan Field<br />

Control Unit – check wiring diagram for<br />

inclusion.<br />

Before setting the parameters for<br />

Option Pakscan ensure Remote<br />

Control Source [Od] has been<br />

selected to [oP] in Section 9.7.<br />

(refer to page 42)<br />

Pakscan set-up screens can be turned<br />

off to provide extra security. The action<br />

of turning screens on or off does not<br />

affect its operation.<br />

Use the + or - key to turn on Pakscan<br />

set-up screens.<br />

Pakscan Set-up Screens ON<br />

PRESS THE<br />

KEY.<br />

The displayed option will flash<br />

indicating that it has been set.<br />

Press the ◗ key to display the Pakscan<br />

set-up screens.<br />

The actuator Pakscan Field Control Unit<br />

must be allocated a unique loop<br />

address.<br />

The actuator must be in “Loopback”<br />

for its address to be set or changed.<br />

Loopback can be achieved in two ways:<br />

1. Turn OFF the master station.<br />

2. Isolate the actuator from the<br />

2-wire control loop.<br />

Using the + or - keys display the<br />

required loop address.<br />

Address to be set within the range<br />

01–F0 Hexadecimal. (refer to table on<br />

page 75).<br />

The actuator Pakscan Field Control Unit<br />

baud rate must be set to the loop baud<br />

rate. For a Pakscan 2-wire control loop<br />

the selected baud rate must be common<br />

to the master station and all the field<br />

control units included in the loop.<br />

The actuator must be in “Loopback”<br />

for its baud rate to be set or changed.<br />

Loopback can be achieved in two ways:<br />

1. Turn OFF the master station.<br />

2. Isolate the actuator from the<br />

2-wire control loop.<br />

PRESS THE<br />

KEY.<br />

The displayed option will flash<br />

indicating that it has been set.<br />

Press the ❖ key to display [Pb].<br />

Continued