- Page 1 and 2: Garney Construction 785 E Warren Ga
- Page 3 and 4: Page 173 Page 174 Page 179 Page 179
- Page 6 and 7: Ward County Water Supply Expansion
- Page 8 and 9: 1513188 HP Page 1 of 5 401 South Hi
- Page 10 and 11: 1513188 HP Page 3 of 5 401 South Hi
- Page 12 and 13: 1513188 HP Page 5 of 5 401 South Hi
- Page 14 and 15: 1513188 HP Page 2 of 5 401 South Hi
- Page 16 and 17: 1513188 HP Page 4 of 5 401 South Hi
- Page 62 and 63: A Tradition of Excellence With the
- Page 64 and 65: Design Details: Models 2FII and MKI
- Page 66 and 67: Suggested Specification for the Pra
- Page 68 and 69:
401 S. Highland Avenue Aurora, Illi
- Page 70 and 71:
AWWA Butterfly Valves Engineering C
- Page 72 and 73:
Scope of Line: AWWA Rubber Seated B
- Page 74 and 75:
Features and Benefits of Henry Prat
- Page 76 and 77:
Dimensional Data: Model 511A, Flang
- Page 78 and 79:
Henry Pratt Model 511 Flanged/ 510
- Page 80 and 81:
Suggested Specification (24" and La
- Page 82 and 83:
401 S. Highland Avenue Aurora, Illi
- Page 84 and 85:
Triton XR-70 Butterfly Valve Engine
- Page 86 and 87:
401 South Highland Avenue Aurora, I
- Page 88 and 89:
Features and Benefits: Triton XR-70
- Page 90 and 91:
Design Details: Triton XR-70 Butter
- Page 92 and 93:
Coatings and Rubber Linings Withsta
- Page 94 and 95:
Valve End Types and Dimensions: Fla
- Page 96 and 97:
Suggested Specifications: Butterfly
- Page 98 and 99:
401 S. Highland Avenue Aurora, Illi
- Page 101 and 102:
A Tradition of Excellence With the
- Page 103 and 104:
HP250II BUTTERFLY VALVE FEATURE
- Page 105 and 106:
HP250II BUTTERFLY VALVE, 125# FLAN
- Page 107 and 108:
401 S. Highland Avenue Aurora, Illi
- Page 109 and 110:
HP350 401 S. Highland Avenue Aurora
- Page 111 and 112:
6" - 48" HP350 Flanged Ends, Manual
- Page 113 and 114:
3”-20” 2FII & Groundhog® Bonde
- Page 115 and 116:
3”-20” 2FII & Groundhog® Bonde
- Page 117 and 118:
3”-20” 2FII & Groundhog® Bonde
- Page 119 and 120:
3”-20” 2FII & Groundhog® Bonde
- Page 121 and 122:
3”-20” 2FII & Groundhog® Bonde
- Page 123 and 124:
3”-20” 2FII & Groundhog® Bonde
- Page 125 and 126:
Triton XR-70,Triton XL & Groundhog
- Page 127 and 128:
Triton XR-70,Triton XL & Groundhog
- Page 129 and 130:
Triton XR-70,Triton XL & Groundhog
- Page 131 and 132:
Triton XR-70,Triton XL & Groundhog
- Page 133 and 134:
Triton XR-70,Triton XL & Groundhog
- Page 135 and 136:
Triton XR-70,Triton XL & Groundhog
- Page 137 and 138:
Triton XR-70,Triton XL & Groundhog
- Page 139 and 140:
24”-48” HP250II Butterfly Valve
- Page 141 and 142:
24”-48” HP250II Butterfly Valve
- Page 143 and 144:
24”-48” HP250II Butterfly Valve
- Page 145 and 146:
24”-48” HP250II Butterfly Valve
- Page 147 and 148:
24”-48” HP250II Butterfly Valve
- Page 149 and 150:
24”-48” HP250II Butterfly Valve
- Page 151 and 152:
24”-48” HP250II Butterfly Valve
- Page 153 and 154:
HP350 Butterfly Valve SAFETY MESSAG
- Page 155 and 156:
HP350 Butterfly Valve Functional De
- Page 157 and 158:
HP350 Butterfly Valve • Valves ar
- Page 159 and 160:
HP350 Butterfly Valve OPERATION Do
- Page 161 and 162:
HP350 Butterfly Valve MAINTENANCE M
- Page 163 and 164:
HP350 Butterfly Valve HOW TO CONTAC
- Page 165 and 166:
Henry Pratt Diviner Position Indica
- Page 167 and 168:
Diviner Position Indicator Table of
- Page 169 and 170:
Diviner Position Indicator INSTALLA
- Page 171 and 172:
Diviner Position Indicator INSTALLA
- Page 173 and 174:
RECOMMENDATIONS FOR EXTENDED STORAG
- Page 175 and 176:
Page 2 of 5 UL/FM HENRY PRATT COMPA
- Page 177 and 178:
Page 4 of 5 UL/FM HENRY PRATT COMPA
- Page 180 and 181:
A Tradition of Excellence With the
- Page 182 and 183:
Scope of Line: VALVE ACTUATORS
- Page 184 and 185:
MANUAL ACTUATORS Open
- Page 186 and 187:
BURIED SERVICE ACTUATOR
- Page 188 and 189:
ACTUATOR EXTENSIONS
- Page 190 and 191:
ACTUATOR EXTENSIONS
- Page 192 and 193:
ACTUATOR EXTENSIONS
- Page 194 and 195:
ACTUATOR EXTENSIONS
- Page 196 and 197:
ACTUATOR EXTENSIONS
- Page 198 and 199:
ACTUATOR EXTENSIONS
- Page 200 and 201:
ACTUATOR EXTENSIONS
- Page 202 and 203:
ACTUATOR EXTENSIONS
- Page 204 and 205:
AUMA Data Sheet AUMA Comm No.: A000
- Page 206:
AUMA Data Sheet AUMA Comm No.: A000
- Page 210 and 211:
PRATT Henry Pratt Company TITLE: OP
- Page 212 and 213:
R Weggebereinheit WSG für Schnecke
- Page 214 and 215:
Technical data valve position indic
- Page 216 and 217:
Technical data valve position indic
- Page 218 and 219:
.
- Page 220 and 221:
.
- Page 222 and 223:
.
- Page 224 and 225:
.
- Page 226 and 227:
.
- Page 228 and 229:
. .
- Page 230 and 231:
. .
- Page 232 and 233:
. .
- Page 234 and 235:
.
- Page 236 and 237:
.
- Page 238 and 239:
.
- Page 240 and 241:
.
- Page 242 and 243:
WSG 90.1 Technical data valve posit
- Page 244 and 245:
Multi-turn gearboxes Bevel gearboxe
- Page 246 and 247:
Operation instructions Bevel gearbo
- Page 248 and 249:
Operation instructions Bevel gearbo
- Page 250 and 251:
Operation instructions Bevel gearbo
- Page 252 and 253:
Operation instructions Bevel gearbo
- Page 254 and 255:
Operation instructions Bevel gearbo
- Page 256 and 257:
Operation instructions Bevel gearbo
- Page 258 and 259:
Operation instructions Bevel gearbo
- Page 260 and 261:
Operation instructions Bevel gearbo
- Page 262 and 263:
Operation instructions Bevel gearbo
- Page 264 and 265:
Operation instructions Bevel gearbo
- Page 266 and 267:
AUMA ACTUATORS (Singapore) Pte Ltd.
- Page 268 and 269:
Part-turn gearboxes Worm gearboxes
- Page 270 and 271:
Operation instructions Worm gearbox
- Page 272 and 273:
Operation instructions Worm gearbox
- Page 274 and 275:
Operation instructions Worm gearbox
- Page 276 and 277:
Operation instructions Worm gearbox
- Page 278 and 279:
Operation instructions Worm gearbox
- Page 280 and 281:
Operation instructions Worm gearbox
- Page 282 and 283:
Operation instructions Worm gearbox
- Page 284 and 285:
Operation instructions Worm gearbox
- Page 286 and 287:
Operation instructions Worm gearbox
- Page 288 and 289:
Operation instructions Worm gearbox
- Page 290 and 291:
Operation instructions Worm gearbox
- Page 292 and 293:
Operation instructions Worm gearbox
- Page 294 and 295:
Operation instructions Worm gearbox
- Page 296 and 297:
Operation instructions Worm gearbox
- Page 298 and 299:
Operation instructions Worm gearbox
- Page 300 and 301:
IQ Electric Motor Actuator Data She
- Page 302 and 303:
IQ Electric Motor Actuator Data She
- Page 304 and 305:
IQ Electric Motor Actuator Data She
- Page 306:
IQ Electric Motor Actuator Data She
- Page 310:
NOT ROTORK SUPPLY X ACTUATOR TERMIN
- Page 319 and 320:
Control and monitoring facilities I
- Page 321 and 322:
IQ - In control IQ - the first valv
- Page 323 and 324:
Wiring Jig built harnesses of indiv
- Page 325 and 326:
Control specification Local Control
- Page 327 and 328:
Indication, monitoring and data log
- Page 329 and 330:
Fieldbus systems Pakscan Rotork’s
- Page 331 and 332:
Actuator circuit diagram - options
- Page 333 and 334:
Emergency Shut Down ESD and Interlo
- Page 335 and 336:
Open/Close maintained control with
- Page 337 and 338:
IQ IQT
- Page 339 and 340:
IQ Range Installation and Maintenan
- Page 341:
This manual provides instruction on
- Page 344 and 345:
1 Health and Safety 2 This manual i
- Page 346 and 347:
4 control only for Open and Close b
- Page 348 and 349:
6 Actuator Alarm Fig. 3.8 The actua
- Page 350 and 351:
8 4.2 IQ10 to IQ35 Non-Thrust Base
- Page 352 and 353:
5 Mounting the Actuator 10 (Refer t
- Page 354 and 355:
12 5.5 IQM Modulating Actuators The
- Page 356 and 357:
6 Cable Connections 14 WARNING: Ens
- Page 358 and 359:
7 Commissioning 16 7.1 The Setting
- Page 360 and 361:
18 7.3 Entering the Actuator Settin
- Page 362 and 363:
Fig. 8 8 Commissioning - Primary Fu
- Page 364 and 365:
C1 Direction to Close 22 Manually o
- Page 366 and 367:
C3 Open Action 24 The actuator can
- Page 368 and 369:
tO Torque Valve Opening 26 The valu
- Page 370 and 371:
Return to Positional Display 28 50
- Page 372 and 373:
30 50 ◗ Positional Display IrDA C
- Page 374 and 375:
9.2 Indication Contacts S1, S2, S3
- Page 376 and 377:
9.3 Control Mode Configuration A1 E
- Page 378 and 379:
A8 External Interlocks A9 Condition
- Page 380 and 381:
9.5 Option CPT [OI] (Current Positi
- Page 382 and 383:
FI Set Point Signal Type Fr Set Poi
- Page 384 and 385:
9.7 Remote Control Source Od Remote
- Page 386 and 387:
Pb Pakscan Baud Rate PF Pakscan Rem
- Page 388 and 389:
PF Pakscan Remote Auxiliary Input P
- Page 390 and 391:
PF Modbus Remote Auxiliary Input 48
- Page 392 and 393:
50 For Modbus module positioning se
- Page 394 and 395:
PF Profibus Remote Auxiliary Input
- Page 396 and 397:
PF Profibus Remote Auxiliary Input
- Page 398 and 399:
PF DeviceNet Remote Auxiliary Input
- Page 400 and 401:
9.12 Bus System Positioning Control
- Page 402 and 403:
9.13 Option Interrupter Timer Setti
- Page 404 and 405:
Example Note 9.14 Setting Tool Loca
- Page 406 and 407:
9.17 Default Options [d1] and [d2]
- Page 408 and 409:
10 Maintenance, Monitoring and Trou
- Page 410 and 411:
H1 Factors Inhibiting Electrical Op
- Page 412 and 413:
H5 Remote Interlocks, Local Control
- Page 414 and 415:
10.2 IrDA Diagnostics & Config. IQ
- Page 416 and 417:
11 Weights and Measures 74 Oil Unle
- Page 418 and 419:
12 IQ Approvals 76 Refer to actuato
- Page 420 and 421:
Denmark Agent Tel: +45 32531777 Fax
- Page 422:
United States of America Houston Ro