Table 10. Startup Procedure <strong>f<strong>or</strong></strong> Image-Sensing Applications<br />

NO. µC SERIALIZER DESERIALIZER<br />

Sets all configuration inputs. If any<br />

configuration inputs are available on<br />

Sets all configuration inputs. If any<br />

configuration inputs are available on<br />

— FC connected to deserializer.<br />

one end of the link but not on the other, one end of the link but not on the other,<br />

always connects that configuration always connects that configuration input<br />

input low.<br />

low.<br />

1 Powers up.<br />

3<br />

Writes deserializer configuration<br />

bits and gets an acknowledge.<br />

Powers up and loads default settings.<br />

Establishes serial link.<br />

—<br />

Powers up and loads default settings.<br />

Locks to serial link signal.<br />

Configuration changed from default settings<br />

(loss-of-lock can occur).<br />

4<br />

Writes serializer configuration<br />

bits. Cannot get an acknowledge<br />

(<strong>or</strong> gets a dummy acknowledge)<br />

if loss-of-lock occurred.<br />

Configuration changed from default<br />

settings.<br />

Relocks the serial link signal.<br />

5<br />

Enables video link by setting<br />

SEREN = 1 (if not enabled<br />

automatically). Cannot get an<br />

acknowledge (<strong>or</strong> gets a dummy<br />

acknowledge) if loss-of-lock<br />

occurred. Waits <strong>f<strong>or</strong></strong> link to be<br />

established (~3ms).<br />

Begins serializing data.<br />

Locks to serial link signal and begins<br />

deserializing data.<br />

SLEEP = 1, VIDEO LINK OR CONFIG<br />

LINK NOT LOCKED AFTER 8ms<br />

SLEEP<br />

WAKE-UP<br />

SIGNAL<br />

POWER-ON<br />

IDLE<br />

SIGNAL<br />

DETECTED<br />

SERIAL PORT<br />

LOCKING<br />

CONFIG LINK<br />

UNLOCKED<br />

CONFIG LINK<br />

LOCKED<br />

CONFIG LINK<br />

OPERATING<br />

PROGRAM<br />

REGISTERS<br />

SERIAL LINK ACTIVITY STOPS OR 8ms ELAPSES AFTER<br />

FC SETS SLEEP = 1<br />

PWDN = HIGH,<br />

POWER-ON<br />

VIDEO LINK<br />

LOCKED<br />

VIDEO LINK<br />

UNLOCKED<br />

0 SLEEP<br />

SEND GPI TO<br />

<strong>GMSL</strong><br />

SERIALIZER<br />

GPI CHANGES FROM<br />

LOW TO HIGH OR<br />

HIGH TO LOW<br />

ALL STATES<br />

PWDN = LOW OR<br />

POWER-OFF<br />

POWER-DOWN<br />

OR<br />

POWER-OFF<br />

VIDEO LINK<br />

OPERATING<br />

PRBSEN = 0<br />

PRBSEN = 1<br />

VIDEO LINK<br />

PRBS TEST<br />

0 SLEEP<br />

Figure 31. State Diagram, Remote Microcontroller Application<br />