Discussion<br />

Topic- Discuss on the following text statement;<br />

“High frequencies increase the relative intensity of the inside surface eddy<br />

currents and so cause greater probe wobble signals. The signals can<br />

therefore be reduced by decreasing the test frequency. This may not be<br />

acceptable because of decreased sensitivity to the outside surface<br />

conditions, so if probe wobble noise is a problem, a slightly larger diameter<br />

probe should be used”.<br />

Hint: Phase lag angle becoming smaller with increasing signal “O” ?<br />