6.5.2 Test reports<br />

A formal test report may be required, but often the results are communicated to<br />

the person responsible by other means, for example, tying an annotated<br />

‘UNSERVICEABLE’ tag to the part, or stamping or signing documentation<br />

pertaining to the parts tested. However, if a test report is required, it should<br />

include at least the following information:<br />

a) Name of the testing authority.<br />

b) Identification of the component(s) tested.<br />

c) Number of the product standard, if applicable.<br />

d) Identification of the written procedure, standard, or other document to which<br />

the testing was performed<br />

e) Identification of the calibration standards used during the test.<br />

f) Results of the test.<br />

g) Date and place of test.<br />

h) Any other information the person responsible for the parts tested requires for<br />

assessment of test results.<br />

i) Identification and signature of the person responsible for the test report.<br />

Refer to Appendix C for example of test report.<br />