The content of written procedures depends on a number of factors, including the<br />

purpose of the test (for example, whether flaw detection, material sorting, or<br />

thickness measurement) and the type of product it applies to, but they should<br />

normally include information on at least the following, if applicable.<br />

(a) Identification of the component(s) to be tested and description of the test<br />

area and flaws sought.<br />

(b) The type of eddy current instrument and probe(s) to be used. If a particular<br />

model of instrument or probe is nominated, acceptable alternatives should<br />

also be stated.<br />

(c) Reference standards.<br />

(d) Other related or referenced documents.<br />

(e) The operating frequency or frequencies.<br />

(f) Full set-up and calibration procedures, including the sensitivity required, and<br />

the frequency of calibration.<br />