FIG. 5.25. Impedance diagram showing the conductivity curve, and the<br />

thickness curve for brass at a frequency of 120 kHz, the f 90 frequency for a<br />

thickness of 0.165 mm. The operating point for this thickness is shown, and liftoff<br />

curves for this and various other thicknesses are also shown.<br />