25.12.2014 Views

EWP Hangers - USP Connectors

EWP Hangers - USP Connectors

EWP Hangers - USP Connectors

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PANEL HANGERS – FHD26<br />

FHD – Straddles the header and receives a joist from both sides.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• In panelized construction, installers are allowed to nail through<br />

both the sheathing and the hanger top flange with (1) 10d nail.<br />

The nail should be centered in the top flange and be no closer<br />

than 1/4˝ from the back or front edge of the top flange.<br />

NEW<br />

Dimensions (in)<br />

Fastener Schedule 3,5<br />

Factored Resistance<br />

Header<br />

Joist<br />

DF-L<br />

S-P-F<br />

Joist <strong>USP</strong><br />

Steel<br />

Top Face Uplift 2 Uplift 2<br />

Size Stock No. Ref. No. Gauge W H D TF 4 Qty Qty Type Qty Type Unit 100% 115% 100% 115%<br />

Lbs 1575 335 1120 235<br />

FHD26 -- -- 18 5-3/8 1-1/2 specify 2 2 2 10d x 1-1/2<br />

kN 7.01 1.49 4.98 1.05<br />

1) Loads listed are per side.<br />

2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) "Specify" denotes the required top flange width that must be specified at the time of ordering.<br />

5) NAILS:<br />

<br />

New products or updated product information are designated in red font.<br />

PURLIN HANGERS – JPF SERIES<br />

W<br />

3 3 /4˝<br />

H<br />

D<br />

FHD<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 20 gauge<br />

Finish: G90 galvanizing<br />

Options: JPF24 and JPF26 are available<br />

in Triple Zinc. To order, add TZ to<br />

stock number, as in JPF24-TZ.<br />

Codes: Load values are derived from<br />

data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page<br />

10.<br />

• Diamond holes allow optional header nailing.<br />

• Joist nails must be driven at a 30° to 45° angle<br />

through the purlin into the header to achieve listed<br />

loads. Standard length “double shear” nails must<br />

be used to achieve listed load values.<br />

• 16d sinkers (9 gauge x 3 1/4˝) may be used where<br />

10d commons are specified with no load reduction.<br />

Raised<br />

dimple allows<br />

30º to 45˚<br />

nailing<br />

Typical JPF24<br />

installation<br />

W 1 1/2˝<br />

JPF24<br />

NEW<br />

H<br />

TF<br />

Typical JPF24<br />

back-to-back installation<br />

Double shear nail<br />

design features<br />

fewer nails and<br />

faster installation<br />

Uses standard<br />

length nails<br />

<strong>Hangers</strong><br />

Purlin<br />

Size<br />

<strong>USP</strong><br />

Stock No.<br />

JPF24<br />

JPF26 PF26 20<br />

Dimensions (in) Fastener Schedule 3,4<br />

Factored Resistance<br />

Header 2 Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Steel<br />

Top Face Floor Uplift 1 Floor Uplift 1 Floor Uplift 1 Floor Uplift 1<br />

Ref. No. Gauge W H TF Qty Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

PF24 20 1-9/16<br />

1-9/16<br />

3-3/8<br />

5-3/8<br />

1-1/16<br />

1-1/16<br />

2<br />

2<br />

-- --<br />

-- --<br />

10d<br />

10d<br />

2<br />

2<br />

10d<br />

10d<br />

1755<br />

1755<br />

675<br />

675<br />

7.81<br />

7.81<br />

3.00<br />

3.00<br />

1245<br />

1245<br />

480<br />

480<br />

5.54<br />

5.54<br />

2.14<br />

2.14<br />

2<br />

2<br />

2<br />

2<br />

10d<br />

10d<br />

2<br />

2<br />

10d<br />

10d<br />

1995<br />

1995<br />

890<br />

890<br />

8.87<br />

8.87<br />

3.96<br />

3.96<br />

1420<br />

1420<br />

630<br />

630<br />

6.32<br />

6.32<br />

2.80<br />

2.80<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) JPF cannot be used back to back on a single ply header when optional nailing is used.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

110<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com