EWP Hangers - USP Connectors
EWP Hangers - USP Connectors
EWP Hangers - USP Connectors
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
PANEL HANGERS – FHD26<br />
FHD – Straddles the header and receives a joist from both sides.<br />
Materials: 18 gauge<br />
Finish: G90 galvanizing<br />
Installation:<br />
• Use all specified fasteners. See Product Notes, page 10.<br />
• In panelized construction, installers are allowed to nail through<br />
both the sheathing and the hanger top flange with (1) 10d nail.<br />
The nail should be centered in the top flange and be no closer<br />
than 1/4˝ from the back or front edge of the top flange.<br />
NEW<br />
Dimensions (in)<br />
Fastener Schedule 3,5<br />
Factored Resistance<br />
Header<br />
Joist<br />
DF-L<br />
S-P-F<br />
Joist <strong>USP</strong><br />
Steel<br />
Top Face Uplift 2 Uplift 2<br />
Size Stock No. Ref. No. Gauge W H D TF 4 Qty Qty Type Qty Type Unit 100% 115% 100% 115%<br />
Lbs 1575 335 1120 235<br />
FHD26 -- -- 18 5-3/8 1-1/2 specify 2 2 2 10d x 1-1/2<br />
kN 7.01 1.49 4.98 1.05<br />
1) Loads listed are per side.<br />
2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />
3) Minimum nail embedment shall be 8 nail diameters (typ).<br />
4) "Specify" denotes the required top flange width that must be specified at the time of ordering.<br />
5) NAILS:<br />
<br />
New products or updated product information are designated in red font.<br />
PURLIN HANGERS – JPF SERIES<br />
W<br />
3 3 /4˝<br />
H<br />
D<br />
FHD<br />
TF<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Materials: 20 gauge<br />
Finish: G90 galvanizing<br />
Options: JPF24 and JPF26 are available<br />
in Triple Zinc. To order, add TZ to<br />
stock number, as in JPF24-TZ.<br />
Codes: Load values are derived from<br />
data submitted to various North<br />
American building code evaluators.<br />
Installation:<br />
• Use all specified fasteners. See Product Notes, page<br />
10.<br />
• Diamond holes allow optional header nailing.<br />
• Joist nails must be driven at a 30° to 45° angle<br />
through the purlin into the header to achieve listed<br />
loads. Standard length “double shear” nails must<br />
be used to achieve listed load values.<br />
• 16d sinkers (9 gauge x 3 1/4˝) may be used where<br />
10d commons are specified with no load reduction.<br />
Raised<br />
dimple allows<br />
30º to 45˚<br />
nailing<br />
Typical JPF24<br />
installation<br />
W 1 1/2˝<br />
JPF24<br />
NEW<br />
H<br />
TF<br />
Typical JPF24<br />
back-to-back installation<br />
Double shear nail<br />
design features<br />
fewer nails and<br />
faster installation<br />
Uses standard<br />
length nails<br />
<strong>Hangers</strong><br />
Purlin<br />
Size<br />
<strong>USP</strong><br />
Stock No.<br />
JPF24<br />
JPF26 PF26 20<br />
Dimensions (in) Fastener Schedule 3,4<br />
Factored Resistance<br />
Header 2 Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />
Steel<br />
Top Face Floor Uplift 1 Floor Uplift 1 Floor Uplift 1 Floor Uplift 1<br />
Ref. No. Gauge W H TF Qty Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />
PF24 20 1-9/16<br />
1-9/16<br />
3-3/8<br />
5-3/8<br />
1-1/16<br />
1-1/16<br />
2<br />
2<br />
-- --<br />
-- --<br />
10d<br />
10d<br />
2<br />
2<br />
10d<br />
10d<br />
1755<br />
1755<br />
675<br />
675<br />
7.81<br />
7.81<br />
3.00<br />
3.00<br />
1245<br />
1245<br />
480<br />
480<br />
5.54<br />
5.54<br />
2.14<br />
2.14<br />
2<br />
2<br />
2<br />
2<br />
10d<br />
10d<br />
2<br />
2<br />
10d<br />
10d<br />
1995<br />
1995<br />
890<br />
890<br />
8.87<br />
8.87<br />
3.96<br />
3.96<br />
1420<br />
1420<br />
630<br />
630<br />
6.32<br />
6.32<br />
2.80<br />
2.80<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />
2) JPF cannot be used back to back on a single ply header when optional nailing is used.<br />
3) Minimum nail embedment shall be 8 nail diameters (typ).<br />
4) NAILS:<br />
New products or updated product information are designated in red font.<br />
110<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com