25.12.2014 Views

EWP Hangers - USP Connectors

EWP Hangers - USP Connectors

EWP Hangers - USP Connectors

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Face Mount <strong>Hangers</strong> – THF series<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Designed to provide lateral support for the top chords of I-Joists<br />

in depths up to 16˝. Eliminates the need for web stiffeners in<br />

most applications (see Web Stiffener Reqd. column in <strong>EWP</strong><br />

Face Mount Hanger Chart for specific applications).<br />

Materials: See <strong>EWP</strong> Face Mount <strong>Hangers</strong> charts,<br />

pages 121-122.<br />

Finish: G90 galvanizing<br />

Options: See Specialty Options chart.<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Install 10d x 1 1 ⁄ 2˝ nails into joist through raised dimple at<br />

a 30° to 45° angle.<br />

• THF Min – Fill all round nail holes.<br />

• THF Max – Fill all round and diamond holes.<br />

Specialty Options Chart – refer to Specialty<br />

Options pages 210 to 211 for additional details.<br />

Typical THF I-Joist<br />

to Joist installation<br />

H<br />

W<br />

2˝<br />

Additional diamond<br />

nail holes for<br />

maximum nailing<br />

Standard round<br />

nail holes for<br />

minimum nailing<br />

THF single<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />

<br />

Not available in<br />

Range <br />

<br />

See Sloped Seat and Skewed<br />

<br />

<br />

Factored<br />

Resistance<br />

Ordering<br />

100% of table load.<br />

<br />

<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Example: THF23925-SK45R<br />

100% of table load<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Example: THF23925-SL30D<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications.<br />

4) Modifications to THF hangers do not feature seat cleats.<br />

80% of table load.<br />

<br />

<br />

See Sloped Seat and Skewed<br />

Example:<br />

THF23925-SK45RSL30D<br />

100% of table load.<br />

<br />

nailing into the support<br />

members end grain.<br />

Add IF,<br />

to product number.<br />

Example: THF23925IF<br />

Dimple allows<br />

30˚ to 45˚<br />

nailing<br />

Typical THF double I-Joist<br />

to LVL installation<br />

Raised Dimple<br />

nail holes allow<br />

30° to 45°<br />

nailing into<br />

I-Joist bottom<br />

flange.<br />

W<br />

D<br />

H<br />

THF double<br />

Seat Cleat®<br />

helps lock<br />

I-Joist into place<br />

for<br />

positive seating<br />

and nailing ease.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Face Mount <strong>Hangers</strong> – HD series<br />

Designed to to support LVL, LSL, and PSL beams and headers in medium load conditions.<br />

Materials: See <strong>EWP</strong> Face Mount <strong>Hangers</strong> charts, pages 122-123.<br />

Finish: G90 galvanizing<br />

Options: See Specialty Options chart.<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Drive bend line nails into header at 45° to achieve listed loads<br />

Drive bend line nails<br />

into header at 45° to<br />

achieve listed loads.<br />

Typical HD<br />

bend line nail installation<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211 for additional details.<br />

Typical HD<br />

installation<br />

118<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />

<br />

See Sloped Seat and Not available in<br />

Range <br />

Skewed <br />

<br />

Factored<br />

Resistance<br />

Ordering<br />

100% of table load.<br />

75% of uplift load on<br />

<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Example: HD410-SK45R<br />

100% of table load<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Example: HD410-SL30D<br />

80% of table load.<br />

75% of uplift load on<br />

<br />

See Sloped Seat and<br />

Skewed<br />

Example:<br />

HD410-SK45RSL30D<br />

100% of table load.<br />

65% of table load when<br />

nailing into the support<br />

members end grain.<br />

Add IF,<br />

to product number.<br />

Example: HD410IF<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.<br />

<strong>Hangers</strong> for square-cut joists are available as a Custom. Further reductions in allowable loads may apply.<br />

4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Bend line<br />

nailing<br />

W<br />

HD<br />

H<br />

D