Column Caps – KCCQ & KECCQ series<br />
Designed to be installed without the need to drill bolt holes, simplifying installation and<br />
maintaining the wood cross section. Installs with WS Wood Screws offering high uplift<br />
capacity. The wood screws provide a lower profile than bolts.<br />
KCCQ – Standard column cap.<br />
KECCQ – End column cap.<br />
Materials: See chart<br />
Finish: <strong>USP</strong> primer<br />
Options: See Specialty Options on pages 62-63.<br />
KCCQ325-4, KCCQ325-6, KCCQ44, KCCQ46, KCCQ525-4,<br />
KCCQ525-6, KCCQ64,KCCQ66, KECCQ325-4, KECCQ325-6,<br />
KECCQ44, KECCQ46, KECCQ525-6, KECCQ64 & KECCQ66<br />
are available in Hot-dip galvanized. To order, add HDG to stock<br />
number, as in KCCQ44-HDG.<br />
Codes: Load values are derived from data submitted to various<br />
North American building code evaluators.<br />
Installation:<br />
• Use all specified fasteners. See Product Notes, page 10.<br />
• WS3 Wood Screws, 1/4˝ dia. x 3˝ long, are supplied with KCCQ and KECCQ<br />
Column Caps.<br />
• Beams shall be designed to support the required loads. Beam shear may limit<br />
loads to less than listed loads for device. A design professional shall determine<br />
the adequacy of the stud to resist published loads.<br />
W 1<br />
L<br />
H<br />
Typical KCCQ44<br />
centre cap<br />
installation<br />
W 1<br />
L<br />
W 2<br />
KCCQ44<br />
H<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Caps & Bases<br />
<strong>USP</strong><br />
Stock No.<br />
Dimensions (in)<br />
Fastener Schedule 4<br />
W 2<br />
KECCQ44<br />
Factored Resistance 3<br />
Typical KECCQ44<br />
end cap<br />
installation<br />
Column<br />
DF-L<br />
S-P-F<br />
Beam or Post Bearing Uplift Bearing Uplift<br />
(100%) 2 (115%) 1,8 (100%) 2 (115%) 1,8<br />
Steel<br />
Ref. No. Gauge W1 W2 H L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />
Centre Column Caps<br />
KCCQ325-4 CCQ3-4SDS2.5 7 3-1/4 3-5/8 6-1/2 11 16 WS3 14 WS3 30940 137.63 12920 57.47 21040 93.59 9170 40.79<br />
KCCQ325-6 CCQ3-6SDS2.5 7 3-1/4 5-1/2 6-1/2 11 16 WS3 14 WS3 30940 137.63 12920 57.47 21040 93.59 9170 40.79<br />
KCCQ44 CCQ44SDS2.5 7 3-5/8 3-5/8 6-1/2 11 16 WS3 14 WS3 34655 154.16 12575 55.94 23565 104.83 8930 40.79<br />
KCCQ45 -- -- 7 3-5/8 5-3/8 6-1/2 11 16 WS3 14 WS3 34655 154.16 12575 55.94 23565 104.83 8930 40.79<br />
KCCQ46 CCQ46SDS2.5 7 3-5/8 5-1/2 6-1/2 11 16 WS3 14 WS3 34655 154.16 12920 57.47 23565 104.83 9170 40.79<br />
KCCQ47 -- -- 7 3-5/8 7-1/8 6-1/2 11 16 WS3 14 WS3 34655 154.16 12575 55.94 23565 104.83 8930 40.79<br />
KCCQ47X -- -- 7 3-5/8 7-1/8 6-1/2 13 16 WS3 14 WS3 40955 182.18 12575 55.94 27850 123.89 8930 40.79<br />
KCCQ48 CCQ48SDS2.5 7 3-5/8 7-1/2 6-1/2 11 16 WS3 14 WS3 34655 154.16 12920 57.47 23565 104.83 9170 40.79<br />
KCCQ525-4 CCQ5-4SDS2.5 3 5-1/4 3-5/8 8 13 16 WS3 14 WS3 59960 266.73 12920 57.47 40775 181.38 9170 40.79<br />
KCCQ525-6 CCQ5-6SDS2.5 3 5-1/4 5-1/2 8 13 16 WS3 14 WS3 59960 266.73 12920 57.47 40775 181.38 9170 40.79<br />
KCCQ525-8 CCQ5-8SDS2.5 3 5-1/4 7-1/2 8 13 16 WS3 14 WS3 59960 266.73 12920 57.47 40775 181.38 9170 40.79<br />
KCCQ57 -- -- 7 5-3/8 7-1/8 6-1/2 11 16 WS3 14 WS3 51975 231.21 12920 57.47 35345 157.23 9170 40.79<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />
2) Bearing loads are based on compression perpendicular to grain values published in the 2001 NDS and soft converted to Limit States Design.<br />
3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.<br />
<br />
5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.<br />
6) The designer shall check post for required loads.<br />
7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.<br />
8) Uplift loads do not apply to splice conditions.<br />
continued on next page<br />