Roof Truss Ties – TR series<br />

Slotted design allows truss to deflect without imposing load on wall below.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Fastener Schedule 6,7 S-P-F<br />

Factored Resistance (115%) 1<br />

Truss Plate DF-L<br />

<strong>USP</strong><br />

Steel<br />

Without Gap 2 3 4 Without Gap 2 3 4<br />

Stock No. Ref. No. Gauge Description Qty Type Qty Type Unit F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2<br />

TR1<br />

<br />

Lbs 105 60 45 45 -- -- -- -- 90 50 35 35 -- -- -- --<br />

18 single slot 1 8d 2 8d<br />

<br />

kN 0.47 0.27 0.20 0.20 -- -- -- -- 0.40 0.22 0.16 0.16 -- -- -- --<br />

TR1T<br />

TR2<br />

<br />

DTC<br />

16<br />

18<br />

single slot<br />

double slot<br />

1<br />

2<br />

8d<br />

8d<br />

2<br />

4<br />

8d<br />

8d<br />

Lbs<br />

Lbs<br />

375<br />

155<br />

-- --<br />

260<br />

205<br />

105<br />

-- --<br />

170<br />

125<br />

-- --<br />

-- --<br />

-- --<br />

320<br />

130<br />

-- --<br />

220<br />

175<br />

90<br />

-- --<br />

140<br />

110<br />

-- --<br />

-- --<br />

-- --<br />

kN<br />

kN<br />

1.67<br />

0.69<br />

-- --<br />

1.16<br />

0.91<br />

0.47<br />

-- --<br />

0.76<br />

0.56<br />

-- --<br />

-- --<br />

-- --<br />

1.42<br />

0.58<br />

-- --<br />

0.98<br />

0.78<br />

0.40<br />

-- --<br />

0.62<br />

0.49<br />

-- --<br />

-- --<br />

-- --<br />

1) Factored resistances have been increased for short-term loading; 5) To achieve F1 loads in both directions, clips must be installed on<br />

no further increase is allowed. both sides of the trussand staggered to avoid nail interference.<br />

2) Truss must be bearing on top plate to achieve the factored resistances 6) Minimum nail embedment shall be 8 nail diameters (typ).<br />

under "Without Gap". 7) NAILS:<br />

New products or updated product information are designated in red font.<br />

<br />

<br />

<br />

<strong>USP</strong><br />

Stock No.<br />

HTC4<br />

Materials:<br />

Finish:<br />

See chart<br />

G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Do not fully set nails.<br />

• Locate nails into the centre of slots.<br />

Heavy Truss Deflection Clip – HTC4<br />

Slotted design allows truss to deflect without imposing load on wall below.<br />

Materials:<br />

Finish:<br />

Codes:<br />

16 gauge<br />

G90 galvanizing<br />

Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Do not fully set nails.<br />

Fastener Schedule 2,4,5<br />

Plate Truss/Rafter<br />

Without Gap 3<br />

Factored Resistance (115%) 1<br />

3<br />

Without Gap 3 3<br />

Top Side<br />

F1 F2 F1 F2 F1 F2 F1 F2<br />

Steel<br />

Ref. No. Gauge Qty Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

HTC4,<br />

16 2 4 10d x 1-1/2 3 10d x 1-1/2 265 1.18 545 2.42 55 0.24 305 1.36 230 1.02 470 2.09 45 0.20 260 1.16<br />

S/HTC4<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Truss/Rafter must be bearing on top plate to achieve the allowable loads under "Without Gap".<br />

3) When installed with maximum 1-1/4" space between truss/rafter and top plate, use loads under "With 1-1/4" Gap".<br />

4) Minimum nail embedment shall be 8 nail diameters (typ).<br />

5) NAILS<br />

Blocking Supports – ZC series<br />

DF-L<br />

D<br />

S-F-P<br />

3 1 /2˝<br />

TR2<br />

2 1/2˝ 2 11/16˝ F2<br />

1 7/8˝<br />

F1<br />

Typical TR2 installation<br />

HTC4<br />

3 1 /4˝<br />

1 15 /16˝<br />

TR1<br />

1˝<br />

1 1/4˝ 2 3/4˝<br />

2˝<br />

F2<br />

NEW<br />

SIZE<br />

1 1 /4˝<br />

TR1T<br />

F1<br />

Typical HTC4<br />

installation<br />

4 1 /4˝<br />

1 3/4˝<br />

Plated Truss<br />

ZC clips secure blocking between joists or trusses which<br />

provides support for drywall or sheathing.<br />

Materials:<br />

Finish:<br />

See chart<br />

G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

1) Factored resistance shall not be increased for other load duration factors.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

ZC4<br />

179<br />

<strong>USP</strong>2240-131<br />

H<br />

W<br />

ZC2<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance 1<br />

Header Blocking DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Vertical Vertical Vertical Vertical<br />

Stock No. Ref. No. Gauge W H D Qty Type Qty Type 100% 100% 100% 100%<br />

ZC2 Z2 20 2-1/4 1-9/16 1-1/2 2 10d x 1-1/2 2 10d x 1-1/2 670 2.98 475 2.11<br />

ZC4 Z4 12 1-1/2 3-9/16 1-3/8 2 10d x 1-1/2 1 10d x 1-1/2 460 2.05 385 1.71<br />

ZC24 Z28 28 2-1/2 1-9/16 1-3/8 10d x 1-1/2 10d x 1-1/2 -- -- -- -- -- -- -- --<br />

ZC34 Z38 28 2-1/2 2-9/16 1-5/16 10d x 1-1/2 10d x 1-1/2 -- -- -- -- -- -- -- --<br />

Typical ZC installation