Hurricane Retrofit Connector – RT16M<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Designed as a retrofit connector for trusses installed on top plates. Can also be<br />

used as a holdown for a roof or floor system.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Tapcon® Concrete Screws are not supplied with RT16M<br />

connector.<br />

• Install Tapcon® Concrete Screws in lower two holes for<br />

Single Top Plate or Conventional Raised Foundation or<br />

Modular Home Installations.<br />

• Moisture barrier may be required.<br />

F 1<br />

Uplift<br />

Typical RT16M<br />

top plate<br />

installation<br />

8 15 /16˝<br />

3 1 /2˝<br />

5˝<br />

1 9 /16˝<br />

F 2<br />

F3<br />

Truss & Rafter<br />

RT16M<br />

<strong>USP</strong><br />

Stock No.<br />

RT16M<br />

Fastener Schedule 2,3,4,5<br />

Steel<br />

Truss/Rafter Top Plate Masonry Block<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Ref. No. Gauge Qty Type Qty Type Qty Type Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3<br />

9 10d x 1-1/2 -- -- -- -- 4 1/4" x 1-3/4" Tapcon 1730 1045 795 190 7.70 4.65 3.54 0.85 1470 1045 795 190 6.54 4.65 3.54 0.85<br />

HM9KT 18<br />

9 10d x 1-1/2 4 16d 2 1/4" x 1-3/4" Tapcon 1690 -- -- -- -- -- -- 7.52 -- -- -- -- -- -- 1470 -- -- -- -- -- -- 6.54 -- -- -- -- -- --<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

2) Install with 1/4" x 1-3/4" Tapcon® Concrete Screws in accordance to manufacturer's installation specifications.<br />

3) Fasteners to be installed to fully grouted and reinforced concrete masonry.<br />

4) Minimum nail embedment shall be 8 nail diameters (typ).<br />

5) Nails:<br />

Factored Resistance (115%) 1<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 159<br />

<strong>USP</strong>2240-131