Anchor Bolts – AB & ABP series<br />
Anchor Bolts are used to secure wood plates to foundation walls. Washers are<br />
available in various package combinations.<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Materials: Bolt: ASTM F 844, Nut: ASTM A 563, Washers: ASTM F 844<br />
Finish: AB126-HDG, AB128-HDG, AB1212-HDG, AB5812-HDG –<br />
Hot-dip galvanized; All others – none<br />
Installation:<br />
• Select appropriate AB or ABP Anchor Bolt.<br />
• Use concrete with minimum compressive strength of<br />
2,000 psi at 28 days<br />
• Nuts and standard washers are included.<br />
• Anchor bolts intended for use to satisfy code<br />
prescribed anchoring of mudsill plates, and shall be<br />
installed as defined in the code.<br />
• Factored resistance shall be derived in accordance<br />
with the code.<br />
<strong>USP</strong><br />
Stock No. Ref. No.<br />
Bolt<br />
Dia. (in)<br />
L<br />
(in)<br />
AB126-HDG -- -- 1/2 6<br />
AB128-HDG -- -- 1/2 8<br />
AB1212-HDG -- -- 1/2 12<br />
AB5812-HDG -- -- 5/8 12<br />
AB6NW -- -- 1/2 6<br />
AB8NW -- -- 1/2 8<br />
ABP6NW -- -- 1/2 6<br />
ABP8NW -- -- 1/2 8<br />
L<br />
ABP<br />
Typical AB<br />
installation<br />
AB<br />
L<br />
Concrete & Masonry<br />
Foundation Anchors – SFA & SFJA series<br />
SFA – Mudsill anchors for retrofit applications. Features a<br />
slotted bend line for easy field adjustment when foundation walls<br />
are slanted.<br />
SFJA – Ties floor joists directly to foundations with bolt fastening.<br />
Materials: 12 gauge<br />
Finish: G90 galvanizing<br />
7˝<br />
F1<br />
Installation:<br />
• Use all specified fasteners. See Product Notes, page<br />
10.<br />
• A design professional must specify anchor bolt type, length,<br />
and embedment. Anchor bolts are laterally loaded. Follow<br />
installation instructions for epoxy adhesive.<br />
• Factored resistance assume a minimum concrete compressive<br />
strength of 2,000 psi.<br />
8˝<br />
SFA8<br />
6˝<br />
Typical SFA installation<br />
Fastener Schedule<br />
Factored Resistance 1<br />
Anchor<br />
Framing<br />
DF-L<br />
S-P-F<br />
<strong>USP</strong><br />
Steel<br />
Bolts<br />
Nails 2,4 Bolts 3 F1 Uplift F1 Uplift<br />
Stock No. Ref. No. Gauge Qty Dia. Qty Type Qty Dia. 115% 115% 115% 115%<br />
SFJA FJA 12 1 5/8 -- -- -- -- 2 5/8 -- -- 1620 -- -- 1360<br />
SFA8 -- -- 12 2 1/2 7 10d x 1-1/2 -- -- -- -- 1085 -- -- 915 -- --<br />
1) The 115% values are short-term loads such as wind and earthquake.<br />
2) Minimum nail embedment shall be 8 nail diameters (typ).<br />
3) Bolts shall conform to ASTM A 307 or better.<br />
4) NAILS:<br />
red font.<br />
Uplift<br />
1 1 /2˝<br />
6˝<br />
6 1 /2˝<br />
Typical SFJA<br />
installation<br />
1 1 /2˝<br />
SFJA<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />
33<br />
<strong>USP</strong>2240-131