EWP Hangers - USP Connectors
EWP Hangers - USP Connectors
EWP Hangers - USP Connectors
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>EWP</strong> Top Mount Hanger Charts continued<br />
<strong>EWP</strong> <strong>Hangers</strong><br />
Joist Size<br />
7 x 24<br />
7 x 26<br />
7 x 28<br />
7 x 30<br />
7 x 32<br />
<strong>USP</strong><br />
Stock No.<br />
BPH7124<br />
PHXU7124<br />
HLBH7124<br />
PHXU7126<br />
HLBH7126<br />
PHXU7128<br />
HLBH7128<br />
PHXU7130<br />
HLBH7130<br />
PHXU7132<br />
HLBH7132<br />
Ref. No.<br />
B7.12/24<br />
HWI424-2<br />
GLTV424-2,<br />
HB7.12/24,<br />
HGLTV7.12/24<br />
B7.12/26,<br />
HB7.12/26,<br />
HWI426-2<br />
GLTV426-2,<br />
HB7.12/26<br />
B7.12/28,<br />
HB7.12/28,<br />
HWI428-2<br />
GLTV428-2,<br />
HB7.12/28<br />
HWI430-2<br />
GLTV430-2,<br />
HGLTV430-2<br />
HWI432-2<br />
GLTV432-2,<br />
HGLTV432-2<br />
Web Stiffener Reqd.<br />
Steel Gauge<br />
x 12<br />
x 7<br />
x<br />
x<br />
7<br />
x 7<br />
x 7<br />
x<br />
x 7<br />
x<br />
7<br />
7<br />
x 7<br />
x 7<br />
7<br />
Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />
Header Joist Header Material (100%)<br />
Uplift 1<br />
W H D L TF Qty Type Qty Type Unit<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
7-1/8<br />
24 3 -- 2-3/16 10 16d 6 10d<br />
24<br />
24<br />
26<br />
26<br />
28<br />
28<br />
30<br />
30<br />
32<br />
32<br />
3-1/4<br />
1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />
2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />
3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />
4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />
5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />
6) NAILS<br />
Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />
6<br />
3-1/4<br />
6<br />
3-1/4<br />
6<br />
3-1/4<br />
6<br />
3-1/4<br />
6<br />
13-1/8<br />
12<br />
13-1/8<br />
12<br />
13-1/8<br />
12<br />
13-1/8<br />
12<br />
13-1/8<br />
12<br />
2-1/2<br />
3-1/8<br />
2-1/2<br />
3-1/8<br />
2-1/2<br />
3-1/8<br />
2-1/2<br />
3-1/8<br />
2-1/2<br />
3-1/8<br />
8<br />
16d 6 10d<br />
15 6 16d<br />
8 16d 6 10d<br />
15<br />
8 16d 6 10d<br />
15<br />
8 16d 6 10d<br />
15<br />
6 16d<br />
8 16d 6 10d<br />
15<br />
6 16d<br />
6 16d<br />
6 16d<br />
DF-L<br />
I-Joist 2<br />
LVL<br />
PSL<br />
LSL<br />
DF-L<br />
SPF<br />
Masonry 3<br />
DF-L 115%<br />
Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />
kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />
Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />
kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />
Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />
kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />
Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />
kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />
Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />
kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />
Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />
kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />
Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />
kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />
Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />
kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />
Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />
kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />
Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />
kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />
Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />
kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />
L<br />
H<br />
TF<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
W<br />
D<br />
142<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com