Hurricane Gusset Angles – HGA series<br />

Designed for attaching gable end trusses to wood top<br />

plates and masonry walls.<br />

Truss & Rafter<br />

HGA10 – Versatile wood-to-wood connector that<br />

satisfies high wind and seismic loading requirements.<br />

HGAM10 – For installation into grouted concrete tie<br />

beam or masonry bond beam. Provides lateral and<br />

uplift resistance.<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• HGAM10 – Install <strong>USP</strong>’s WS15 Wood Screws into<br />

the truss and drill holes for wedge bolts. Install wedge<br />

bolts into concrete block per manufacturer’s<br />

recommendation.<br />

• HGA10 – Install with <strong>USP</strong>’s WS3 Wood Screws into<br />

top plate, and WS15 Wood Screws into the truss.<br />

• WS Wood Screws are included with HGA10 angles.<br />

• WS Wood Screws and Wedge bolts are included with<br />

HGAM10 angles.<br />

• Moisture barrier may be required.<br />

Uplift<br />

F 1<br />

F 3<br />

F 2<br />

Typical HGA10 installation<br />

Embossed<br />

gussets improve<br />

lateral load<br />

resistance<br />

3 1 /2˝<br />

F 1<br />

Moisture barrier<br />

not shown<br />

3˝<br />

Typical HGAM10 installation<br />

Embossed<br />

gussets improve<br />

lateral load<br />

resistance<br />

3 1 /2˝<br />

3˝<br />

F2<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

HGA10<br />

2˝<br />

HGAM10<br />

2 7/8˝<br />

Fastener Schedule 2<br />

Factored Resistance (115%) 1<br />

Rafter/Truss Plate 3 DF-L (Lbs) DF-L (kN)<br />

S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Stock No. Ref. No. Gauge Qty Type Qty Type F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift<br />

HGA10KT HGA10KT 14 4 WS15 4 WS3 1365 1620 865 1330 6.07 7.21 3.85 5.92 1175 1395 745 1145 5.23 6.21 3.31 5.09<br />

HGAM10KT HGAM10KTA 14 4 WS15 4 1/4 1115 1150 765 945 4.96 5.12 3.40 4.20 955 990 660 815 4.25 4.40 2.94 3.63<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />