Post Beam Corner – PBC series<br />
The PBC series is a one-piece connector designed to secure two<br />
mitered beams on a corner post while providing uplift capacity.<br />
Materials: 18 gauge<br />
Finish: G-185 galvanizing<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Installation:<br />
• Use all specified fasteners. See Product Notes, page 10.<br />
• Install PBC on outside corner of post forming tabs to inner side<br />
of post.<br />
• Assumes beam members are bevel cut at corner.<br />
Dimensions (in) Fastener Schedule 2,3<br />
Factored Resistance 1<br />
Post Beam<br />
DF-L (115%) S-P-F (115%)<br />
F1 F2 Uplift F1 F2 Uplift<br />
Post <strong>USP</strong><br />
Steel<br />
Size Stock No. Ref. No. Gauge W L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />
4 x 4 PBC44-TZ -- -- 18 4-15/16 6-1/2 8 16d HDG 8 16d HDG 900 4.00 900 4.00 1800 8.01 775 3.45 775 3.45 1555 6.92<br />
6 x 6 PBC66-TZ -- -- 18 6-15/16 6-1/2 8 16d HDG 8 16d HDG 900 4.00 900 4.00 1800 8.01 775 3.45 775 3.45 1555 6.92<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for<br />
other load durations in accordance with the code.<br />
2) Minimum nail embedment shall be 8 nail diameters (typ).<br />
3) NAILS:<br />
Typical PBC<br />
installation<br />
W<br />
PBC<br />
W<br />
L<br />
Composite Post Bases – CPB series<br />
The CPB is made of corrosion resistant composite material<br />
compatible with preservative treated lumber. Provides code<br />
required 1˝ stand-off and can be used with rough lumber sizes.<br />
Materials: High Strength composite<br />
Installation:<br />
• Attach base to post with (4) 10d HDG nails.<br />
• Attach post to concrete using 1/2˝ diameter rod into concrete and<br />
extend into wood member.<br />
• Not recommended for fence posts or other unrestrained (not<br />
fixed or fastened at top) applications. These anchors are not<br />
designed to resist overturning (moment) loads.<br />
Caps & Bases<br />
Typical CPB<br />
installation<br />
Dimensions (in) Bottom<br />
Fastener Schedule 5 Factored Concrete Bearing<br />
Surface<br />
Resistance 1,2 Strength 3,4<br />
Post <strong>USP</strong><br />
Bearing<br />
Size Stock No. Ref. No. W1 W2 Area Qty Type Lbs kN Lbs kN<br />
4 x 4 CPB44 CPS4 3-1/4 3-1/4 2.2 4 10d HDG 5235 23.29 6545 29.11<br />
4 x 6 CPB46 CPS46 3-5/16 5-5/16 3.3 4 10d HDG 6810 30.29 9820 43.68<br />
5 x 5 CPB55 CPS5 4-1/8 4-1/8 3.0 4 10d HDG 6295 28.00 8925 39.70<br />
6 x 6 CPB66 CPS6 5-5/16 5-5/16 3.9 4 10d HDG 8570 38.12 11600 51.60<br />
8 x 8 CPB88 CPS7 7-1/4 7-1/4 6.4 4 10d HDG 12490 55.56 19040 84.70<br />
1) Loads shall not be increased for short-term loading.<br />
2) Loads require a minimum 650 psi wood compressive strength.<br />
3) Concrete Design Bearing Strength = Ø (0.85 f' C A 1 ) with f' C = 2,500 psi. ACI 318-02, Section 10.17.1.<br />
4) Design Bearing Strength has been increased assuming (A 2 / A 1 ) 0.5 per ACI 318-02, Section 10.17.1.<br />
5) NAILS:<br />
W 1<br />
CPB<br />
W 2<br />
1˝<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com 59<br />