Slope/Skew <strong>Hangers</strong> – LSSH series<br />
<strong>EWP</strong> <strong>Hangers</strong><br />
The LSSH series connects rafters to ridge beams in vaulted<br />
roof structures. This series is field adjustable to meet a<br />
variety of skew and/or slope applications. Slopes to any pitch<br />
up to 45° up or down and skews up to 45° right or left.<br />
Materials: See chart<br />
Finish: G90 galvanizing; LSSH15-TZ – G-185<br />
Triple Zinc galvanizing<br />
Options: LSSH210 and LSSH31 are available in Triple<br />
Zinc. To order, add TZ to stock number, as in<br />
LSSH210-TZ. LSSH15 and LSSH210 are<br />
available in Stainless steel. To order, add SS<br />
to stock number, as in LSSH210-SS.<br />
Codes: Factored resistances are derived from data<br />
submitted to various North American building<br />
code evaluators and are in accordance with<br />
CSA O86-09.<br />
Installation:<br />
• Use all specified fasteners. See Product Notes, page 10.<br />
Steps:<br />
1. Position LSSH connector against plumb-cut end of rafter joist.<br />
Fasten joist side flanges with 10d (0.148") x 11/2˝ nails.<br />
Bend seat up to fit against joist bottom and drive<br />
(1) 10d (0.148") x 11/2˝ nail through bottom seat into rafter<br />
bottom. Drive (2) 10d (0.148") x 11/2˝ nails at downward<br />
angle through dimpled nailing guides.<br />
2. Lean connector and rafter end against ridge beam at desired<br />
position. Install 10d (0.148" x 3") or 16d (0.162" x 3 1/2˝) nails<br />
through nail holes into ridge beam at right 90° angle.<br />
If skewing the rafter, only drive nails into ridge beam on inside<br />
flange.<br />
3. Bend outside flange to desired angle.<br />
4. Hammer outside flange until edge touches header. Fasten<br />
outside flange to ridge by driving 10d (0.148" x 3") or<br />
16d (0.162" x 3 1/2˝) nails through nail holes.<br />
• Web stiffeners are required for all wood I-Joist installations.<br />
2<br />
skew to 45˚ 45° maximum<br />
Slope to<br />
45˚ up<br />
or down<br />
LSSH210<br />
1<br />
3 & 4<br />
Typical LSSH179<br />
installation<br />
W 2<br />
Slope to<br />
45˚ up<br />
or down<br />
W 1<br />
LSSH35<br />
Dimensions (in)<br />
Fastener Schedule 2,3<br />
Factored Resistance<br />
Header Rafter DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />
Rafter <strong>USP</strong><br />
Steel<br />
Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />
Width Stock No. Ref. No. Gauge W1 W2 H Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />
SLOPED ONLY HANGERS<br />
1-1/2 LSSH15-TZ<br />
LSU26, LSU26Z,<br />
LSSU28, LSSU28Z<br />
18 1-9/16 1-3/4 5-1/16 6 10d HDG 7 10d x 1-1/2 HDG 1640 1395 7.30 6.21 1165 865 5.18 3.85<br />
1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />
1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />
2 - 2-1/8 LSSH20<br />
LSSUI2.06,<br />
LSSU2.1<br />
18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1030 8.27 4.58<br />
2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1030 8.27 4.58<br />
2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 18 16d 12 10d x 1-1/2 4260 2250 18.95 10.01 3025 1390 13.46 6.18<br />
2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 18 16d 12 10d x 1-1/2 4260 2250 18.95 10.01 3025 1390 13.46 6.18<br />
3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 18 16d 12 10d x 1-1/2 5230 2985 23.27 13.28 3715 1845 16.53 8.21<br />
3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 18 16d 12 10d x 1-1/2 5230 2985 23.27 13.28 3715 1845 16.53 8.21<br />
SKEWED HANGERS or SLOPED & SKEWED HANGERS<br />
1-1/2 LSSH15-TZ<br />
LSU26, LSU26Z,<br />
LSSU28, LSSU28Z<br />
18 1-9/16 1-3/4 5-1/16 6 10d HDG 7 10d x 1-1/2 HDG 1340 1395 5.96 6.21 950 865 4.23 3.85<br />
1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />
1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />
2 - 2-1/8 LSSH20<br />
LSSUI2.06,<br />
LSSU2.1<br />
18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1140 8.27 5.07<br />
2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1140 8.27 5.07<br />
2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 14 16d 12 10d x 1-1/2 2985 2250 13.28 10.01 2120 1390 9.43 6.18<br />
2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 14 16d 12 10d x 1-1/2 2985 2250 13.28 10.01 2120 1390 9.43 6.18<br />
3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 14 16d 12 10d x 1-1/2 3145 2985 13.99 13.28 2235 1845 9.94 8.21<br />
3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 14 16d 12 10d x 1-1/2 3145 2985 13.99 13.28 2235 1845 9.94 8.21<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />
2) Minimum nail embedment shall be 8 nail diameters (typ).<br />
3) NAILS:<br />
W2<br />
W1<br />
W2<br />
3˝<br />
H<br />
W2<br />
3˝<br />
H<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
144<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com