20.01.2015 Views

Safety_Series_041_1975 - gnssn - International Atomic Energy ...

Safety_Series_041_1975 - gnssn - International Atomic Energy ...

Safety_Series_041_1975 - gnssn - International Atomic Energy ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

This publication is no longer valid<br />

Please see http://www.ns-iaea.org/standards/<br />

ANNEX I<br />

SAMPLING, ANALYSIS AND REPORTING PROCEDURES [15]<br />

INTRODUCTION<br />

The selection of sam pling equipm ent, the method o f sam ple<br />

preparation, and the m easuring instrum ents depends on the nature<br />

and activity o f the radioactive m ateria l that may be relea sed to the<br />

environm ent. In an econ om ica l p rogram m e the m ethods and<br />

instrum ents used should be adequate to m eet the o b je ctiv e s, but they<br />

should, in gen eral, be the sim plest that w ill enable this to be done.<br />

The m aterials that may have to be m onitored include a ir, w ater,<br />

foodstu ffs, vegetation, s o il, fishing gear. In m ost ca ses a r e p r e ­<br />

sentative sam ple of the m aterial is collected and its activity is<br />

m easured either at the point of collection or later in the laboratory.<br />

Instrumentation m ust be provided for sam pling and for activity<br />

determ inations.<br />

AIR SAMPLING<br />

Sam ples o f airborn e particulates are norm ally collected on a<br />

filter using an air pump and a flow -m easu rin g d ev ice. A ch arcoa l<br />

filter can be placed after the main filte r to co lle ct iodine. The<br />

collected sam ples may be subjected to g ross beta activity m ea su rem<br />

ents, radionuclide analysis, g a m m a -sp ectrom etric analysis,<br />

p article size studies o r autoradiography. If gam m a-sp ectrom etry<br />

is called fo r, the volum e o f air sam pled should be not le s s than<br />

about 300 m 3, hence sev era l sam ples may be com posited to provide<br />

sufficient activity. The sam pling system should be mounted in a<br />

sh elter and the d isch arge point located in such a m anner that<br />

recircu la tion o f the air is prevented.<br />

C onsiderable judgem ent m ust be ex ercised in the selection o f the<br />

air sam pling sites. In gen eral, the sam plers should be placed at<br />

three sites of m axim um predicted g rou n d -level concentrations<br />

39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!