TAC Pneumatic Products Catalog
TAC Pneumatic Products Catalog
TAC Pneumatic Products Catalog
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
R527 Series, R528 Series (2368-5xx Series)<br />
<strong>TAC</strong> PNEUMODULAR � Electric-<strong>Pneumatic</strong> Relays<br />
The electric-pneumatic relays are three-way,<br />
two-position, electrically activated air valves for<br />
use in pneumatic control systems where the<br />
application requires a variety of switching,<br />
diverting, or interlocking functions, actuated by an<br />
electrical circuit. The R527 Series switches one<br />
SPDT pneumatic circuit, while the R528 Series are<br />
designed with DPDT pneumatic switching<br />
(switches two independent SPDT pneumatic<br />
circuits simultaneously).<br />
Features:<br />
• R527 Series provides SPDT pneumatic switching (N.C.,<br />
N.O., C).<br />
• R528 Series provides DPDT pneumatic switching (N.C.,<br />
N.O., C), plus (N.C.2, N.O.2, C2). Switches two separate<br />
circuits simultaneously.<br />
• Manual/auto switch (permits control system testing without<br />
starting and stopping electrical equipment).<br />
• All ports clearly labeled. Ports align with MCS-S terminals.<br />
• <strong>TAC</strong> PNEUMODULAR: Must be mounted on MCS-Socket<br />
and used with MCS-EC electrical connector.<br />
Model Chart<br />
Model No.<br />
Specifications<br />
Wholesale<br />
Model No.<br />
Coil<br />
Voltage<br />
R527-24DC 2368-500 24 Vdc<br />
R527-24 2368-501 24 Vac<br />
R527-110 2368-502 110 Vac<br />
R527-230 2368-503 208 to 240 Vac<br />
R528-24DC 2368-520 24 Vdc<br />
R528-24 2368-521 24 Vac<br />
R528-110 2368-522 110 Vac<br />
R528-230 2368-523 208 to 240 Vac<br />
Switch<br />
Action<br />
Output<br />
Action<br />
3 to 15 psig.<br />
SPDT models (R527 Series) Coil de-energized, C and NO are connected. Coil energized, C and NC are connected.<br />
DPDT models (R528 Series)<br />
Coil de-energized, C and NO are connected, C2 and NO2 are connected. Coil energized, C and NC<br />
are connected, C2 and NC2 are connected.<br />
Maximum ambient temperature 140�F (60�C).<br />
Supply air pressure Clean, dry, oil free air required (Ref. EN-123).<br />
Nominal 20 to 25 psig (138 to 172 kPa).<br />
Maximum<br />
Connections<br />
30 psig (207 kPa).<br />
Air Barbed fittings for 1/4 in. O.D. polyethylene or 5/32 in. I.D. polyurethane tubing.<br />
Electrical<br />
96 © Copyright 2006 <strong>TAC</strong>. All Rights Reserved. F-27383-1<br />
AUTO<br />
MANUAL<br />
M NC NO C S<br />
SPDT<br />
DPDT<br />
Purchase separately the MCS-EC contact assembly with screw terminals and the MCS-EB electrical<br />
barrier.<br />
R527<br />
Series,<br />
R528<br />
Series<br />
(2368-5xx<br />
Series)