TK-18xx Series, TKR-18xx Series<br />

Figure 1 Standard Covers.<br />

Figure 2 Aspirated Thermostat Cover.<br />

Figure 3 Optional Covers. (For quantities of 24 or more of same part number).<br />

Add “dash number” (-xxx) suffix to base part number for desired option. TKR-18x1 available with -116 options only.<br />

For metal covers, specify TK2-18x1-xx.<br />

Specifications<br />

Thermostat<br />

Proportional two pipe type. Thermostat maintains constant branch pressure when temperature is<br />

between dial setpoints.<br />

Sensing elements Two bimetals.<br />

Control dial range Two independent with stops. Refer to Model Chart.<br />

Throttling range<br />

Adjustable 2 to 10�F/10 psi, change in branch pressure when temperature is not between dial<br />

setpoints, factory set at 4�F/10 psi.<br />

Output air signal 0.5 psig (3.4 kPa) to supply air pressure -0.5 psig (-3.4 kPa).<br />

Zero energy band pressure Adjustable 5 to 11 psig (34 to 76 kPa), factory set at 8 psig (55 kPa).<br />

Action<br />

Ambient limits<br />

Refer to Model Chart.<br />

Shipping -40 to 150�F (-40 to 65�C). 0 to 98% R.H., non-condensing.<br />

Operating 20 to 115�F (-7 to 46�C). 10 to 98% R.H., non-condensing.<br />

Supply air pressure Clean, oil free, dry air required (reference EN-123).<br />

Nominal 20 psig (138 kPa).<br />

Minimum 15 psig (103 kPa).<br />

Maximum<br />

Air connections<br />

30 psig (207 kPa).<br />

Main (black) 5/32 in. dia. spring reinforced plastic tube.<br />

Branch (white) 5/32 in. dia. spring reinforced plastic tube.<br />

146<br />

F -399*<br />

C -398*<br />

F<br />

C -116<br />

-400**<br />

-410**<br />

-600<br />

with<br />

-403*<br />

-413*<br />

Insert<br />

Insert<br />

Aspirated model<br />

(requires AT-509)<br />

Note: Not available on<br />

TKR-18x1 models.<br />

Available to <strong>TAC</strong> only.<br />

-404<br />

-414<br />

* Units have external thermometers.<br />

** Units have internal setpoint adjustment;<br />

setpoint can be seen externally.<br />

Knob(s) are provided to modify the<br />

unit to exterrnal adjustment.<br />

-400<br />

The only optional covers<br />

available to Controline<br />

and Uni-Line.<br />

© Copyright 2006 <strong>TAC</strong>. All Rights Reserved. F-27383-1