Final FONSI and EA for hot cargo pad on Kirtland AFB - Kirtland Air ...
Final FONSI and EA for hot cargo pad on Kirtland AFB - Kirtland Air ...
Final FONSI and EA for hot cargo pad on Kirtland AFB - Kirtland Air ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<str<strong>on</strong>g>Final</str<strong>on</strong>g> <str<strong>on</strong>g>EA</str<strong>on</strong>g> Addressing C<strong>on</strong>structi<strong>on</strong>, Operati<strong>on</strong>, <str<strong>on</strong>g>and</str<strong>on</strong>g> Maintenance of a Hot Cargo Pad<br />
The most recent emissi<strong>on</strong>s inventories <str<strong>on</strong>g>for</str<strong>on</strong>g> Bernalillo County <str<strong>on</strong>g>and</str<strong>on</strong>g> the AMRGI AQCR are shown in<br />
Table 3-4. Bernalillo County is c<strong>on</strong>sidered the local area of influence, <str<strong>on</strong>g>and</str<strong>on</strong>g> the AMRGI AQCR is<br />
c<strong>on</strong>sidered the regi<strong>on</strong>al area of influence <str<strong>on</strong>g>for</str<strong>on</strong>g> the air quality analysis.<br />
Locati<strong>on</strong><br />
Table 3-4. Local <str<strong>on</strong>g>and</str<strong>on</strong>g> Regi<strong>on</strong>al <strong>Air</strong> Emissi<strong>on</strong>s Inventory <str<strong>on</strong>g>for</str<strong>on</strong>g> 2002<br />
NO x<br />
(tpy)<br />
VOC<br />
(tpy)<br />
CO<br />
(tpy)<br />
SO 2<br />
(tpy)<br />
PM 10<br />
(tpy)<br />
PM 2.5<br />
(tpy)<br />
Bernalillo County, New<br />
Mexico<br />
24,930 24,310 185,250 1,568 61,892 8,183<br />
AMRGI AQCR 36,778 31,651 245,346 2,619 137,376 16,676<br />
Source: USEPA 2009b<br />
The DOE, Energy In<str<strong>on</strong>g>for</str<strong>on</strong>g>mati<strong>on</strong> Administrati<strong>on</strong> states that in 2005, gross CO 2 emissi<strong>on</strong>s in New Mexico<br />
were 59.5 milli<strong>on</strong> metric t<strong>on</strong>s (DOE 2009).<br />
The Albuquerque-Bernalillo County <strong>Air</strong> Quality C<strong>on</strong>trol Board (AQCB) is the air polluti<strong>on</strong> c<strong>on</strong>trol<br />
authority <str<strong>on</strong>g>for</str<strong>on</strong>g> Bernalillo County while the AEHD-AQD h<str<strong>on</strong>g>and</str<strong>on</strong>g>les air quality management functi<strong>on</strong>s. There<br />
are various sources <strong>on</strong> the installati<strong>on</strong> that emit criteria <str<strong>on</strong>g>and</str<strong>on</strong>g> hazardous air pollutants (HAPs), including<br />
emergency generators, boilers, <str<strong>on</strong>g>hot</str<strong>on</strong>g> water heaters, fuel storage tanks, gasoline service stati<strong>on</strong>s, surface<br />
coating, aircraft engine testing, <str<strong>on</strong>g>and</str<strong>on</strong>g> miscellaneous chemical usage. As required by the<br />
Albuquerque-Bernalillo County AQCB regulati<strong>on</strong>s, Kirtl<str<strong>on</strong>g>and</str<strong>on</strong>g> <strong>AFB</strong> estimates annual emissi<strong>on</strong>s from<br />
stati<strong>on</strong>ary sources <str<strong>on</strong>g>and</str<strong>on</strong>g> provides this in<str<strong>on</strong>g>for</str<strong>on</strong>g>mati<strong>on</strong> to the AEHD-AQD. Table 3-5 summarizes the calendar<br />
year 2008 air emissi<strong>on</strong>s inventory <str<strong>on</strong>g>for</str<strong>on</strong>g> Kirtl<str<strong>on</strong>g>and</str<strong>on</strong>g> <strong>AFB</strong>.<br />
Table 3-5. Calendar Year 2008 <strong>Air</strong> Emissi<strong>on</strong>s Inventory <str<strong>on</strong>g>for</str<strong>on</strong>g> Kirtl<str<strong>on</strong>g>and</str<strong>on</strong>g> <strong>AFB</strong><br />
NO x<br />
(tpy)<br />
VOC<br />
(tpy)<br />
CO<br />
(tpy)<br />
SO 2<br />
(tpy)<br />
PM 10<br />
(tpy)<br />
2008 Actual Emissi<strong>on</strong>s 12.8 60.0 13.0 1.1 8.1<br />
Source: K<strong>AFB</strong> 2009a<br />
The AEHD-AQD has fugitive dust-c<strong>on</strong>trol requirements in 20.11.20 New Mexico Administrative Code<br />
(NMAC), Fugitive Dust C<strong>on</strong>trol. A fugitive dust-c<strong>on</strong>trol c<strong>on</strong>structi<strong>on</strong> permit is required <str<strong>on</strong>g>for</str<strong>on</strong>g> projects<br />
disturbing 0.75 acres or more, as well as the demoliti<strong>on</strong> of buildings c<strong>on</strong>taining more than 75,000 cubic<br />
feet of space. An applicati<strong>on</strong> <str<strong>on</strong>g>for</str<strong>on</strong>g> a fugitive dust-c<strong>on</strong>trol c<strong>on</strong>structi<strong>on</strong> permit from the AEHD-AQD must<br />
be submitted a minimum of 30 days prior to the start of c<strong>on</strong>structi<strong>on</strong>. As stated in 20.11.20.12 NMAC<br />
General Provisi<strong>on</strong>s, each pers<strong>on</strong> shall use reas<strong>on</strong>ably available c<strong>on</strong>trol measures or any other effective<br />
c<strong>on</strong>trol measure during active operati<strong>on</strong>s or <strong>on</strong> inactive disturbed surface areas, as necessary to prevent<br />
the release of fugitive dust, whether or not the pers<strong>on</strong> is required by 20.11.20 NMAC to obtain a fugitive<br />
dust-c<strong>on</strong>trol permit. This regulati<strong>on</strong> also c<strong>on</strong>tains a provisi<strong>on</strong> <str<strong>on</strong>g>for</str<strong>on</strong>g> buildings c<strong>on</strong>taining asbestosc<strong>on</strong>taining<br />
materials (ACMs) as stated in 20.11.20.22 NMAC Demoliti<strong>on</strong> <str<strong>on</strong>g>and</str<strong>on</strong>g> Renovati<strong>on</strong> Activities;<br />
Fugitive Dust C<strong>on</strong>trol C<strong>on</strong>structi<strong>on</strong> Permit <str<strong>on</strong>g>and</str<strong>on</strong>g> Asbestos Notificati<strong>on</strong> Requirements: “All demoliti<strong>on</strong> <str<strong>on</strong>g>and</str<strong>on</strong>g><br />
renovati<strong>on</strong> activities shall employ reas<strong>on</strong>ably available c<strong>on</strong>trol measures at all times, <str<strong>on</strong>g>and</str<strong>on</strong>g>, when removing<br />
asbestos-c<strong>on</strong>taining material (ACM), shall also comply with the federal st<str<strong>on</strong>g>and</str<strong>on</strong>g>ards incorporated in<br />
20.11.64 NMAC, Emissi<strong>on</strong> St<str<strong>on</strong>g>and</str<strong>on</strong>g>ards <str<strong>on</strong>g>for</str<strong>on</strong>g> Hazardous <strong>Air</strong> Pollutants <str<strong>on</strong>g>for</str<strong>on</strong>g> Stati<strong>on</strong>ary Sources. A pers<strong>on</strong><br />
who demolishes or renovates any commercial building, residential building c<strong>on</strong>taining five or more<br />
dwellings, or a residential structure that will be demolished in order to build a n<strong>on</strong>residential structure or<br />
Kirtl<str<strong>on</strong>g>and</str<strong>on</strong>g> <strong>AFB</strong>, NM January 2011<br />
3-13