The Main Screen<br />

Device diagnosis<br />

Opens the "device diagnosis"<br />

window. Here you can check if<br />

the system hardware is working<br />

properly.<br />

To check the system:<br />

a) Attach the battery clip and turn it on by pressing the<br />

button.<br />

b) Open the "Device diagnosis" from the main menu.<br />

c) Move the club with triplet (or triplet alone) in front of the<br />

basic unit.<br />

d) The front side of the triplet must show into direction of the<br />

basic unit.<br />

e) Move the triplet around in distance of 50 to 100 cm to the<br />

basic unit and check if all three signal lamps (Marker1 to<br />

Marker3) become green. If this is the case the system is<br />

OK.<br />

The signals should stay green while moving around in the<br />

normal operational area.<br />

If one of the signal lamps never gets green probably one<br />

sensor (ultrasonic marker) of the triplet is defective.<br />

If none of the signal lamps are turning green check the following:<br />

a) Check the LED light on the battery clip:<br />

If it is blinking red, batteries are low. Exchange the batteries<br />

and try again.<br />

b) Check the LED light on the battery clip:<br />

If it is off, the system is not activated or the batteries are<br />

dead. Try to activate the system by pressing the button. If<br />

nothing happens exchange the batteries and try again.<br />

Page 53