4.9 <strong>AT</strong>+IPR<br />

4.9 <strong>AT</strong>+IPR Bit Rate<br />

<strong>AT</strong>+IPR allows to query and set the bit rate of the <strong>TC63i</strong>'s asynchronous serial interfaces (UART).<br />

The test command returns the values of supported automatically detectable bit rates and the values of the supported<br />

fixed bit rates.<br />

The read command returns the the currently set value.<br />

The write command specifies the bit rate to be used for the interface. Delivery bit rate value () is<br />

115200bps on ASC0 and 115200bps on ASC1. This setting will not be restored with <strong>AT</strong>&F.<br />

If using a fixed bit rate, make sure that both <strong>TC63i</strong> and TA are configured to the same rate. A selected fixed bit<br />

rate takes effect after the write command returns OK and is stored in non-volatile memory. It is not recommended<br />

to set bit rates lower than 9600 bps in order to avoid timing problems (see Section 1.5, Communication between<br />

Customer Application and <strong>TC63i</strong> for details about timing).<br />

In case of autobauding mode (<strong>AT</strong>+IPR=0) the detected TA bit rate will not be saved and, therefore, needs to be<br />

resynchronized after any restart of the ME (for details refer Section 4.9.1, Autobauding). If autobauding is activated,<br />

the TA will automatically recognize bit rate, character framing and parity format (refer <strong>AT</strong>+ICF) currently<br />

used by the TE.<br />

In Multiplex mode the write command will not change the bit rate currently used, but the new bit rate will be stored<br />

and becomes active, when the module is restarted.<br />

The current setting of <strong>AT</strong>+IPR will be preserved when you download firmware (i.e. a firmware update does not<br />

restore the factory setting) or in the event of power failure.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>+IPR=?<br />

Response(s)<br />

+IPR: (list of supported auto-detectable s) , (list of supported fixed-only s)<br />

OK<br />

Read <strong>Command</strong><br />

<strong>AT</strong>+IPR?<br />

Response(s)<br />

+IPR: <br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>+IPR=<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last Reference(s)<br />

- + ± - ± ± ± - + - V.250<br />

Parameter Description<br />

(num)(&V)<br />

bit rate per second (bps)<br />

0 Activates autobauding. Not supported on ASC1. See Section 4.9.1, Autobauding<br />

for further details.<br />

300<br />

600<br />

1200<br />

<strong>TC63i</strong>_<strong>AT</strong>C_V01.100 Page 116 of 547 11/10/08<br />