28.04.2015 Views

TC63i AT Command Set

TC63i AT Command Set

TC63i AT Command Set

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>TC63i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

<br />

8.10 <strong>AT</strong>^MONP<br />

8.10 <strong>AT</strong>^MONP Monitor neighbor cells<br />

The <strong>AT</strong>^MONP supplies information of up to six neighbor cells. There are two ways to retrieve the information:<br />

once on request by using the execute command or automatically every seconds by using the write<br />

command. To stop the periodic presentation type "<strong>AT</strong>" or "at".<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^MONP=?<br />

Response(s)<br />

^MONP:(list of supported s)<br />

OK<br />

Exec <strong>Command</strong><br />

<strong>AT</strong>^MONP<br />

Response(s)<br />

See: Section 8.10.1, <strong>AT</strong>^MONP responses<br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>^MONP=<br />

Response(s)<br />

See: Section 8.10.1, <strong>AT</strong>^MONP responses<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

- + + + + + + - - -<br />

Parameter Description<br />

(num)<br />

Display period in seconds<br />

1...254<br />

Notes<br />

• During a connection some neighbor cell parameters cannot be updated. Therefore, the parameters MCC,<br />

MNC, C1 and C2 equal zero until the connection is released.<br />

• To some extent, the cell monitoring command <strong>AT</strong>^SMONC covers the same parameters. The receiving level,<br />

for example, can be queried with both commands. Yet the resulting values may be slightly different, even<br />

though obtained over a time period of a few seconds. This is quite normal and nothing to worry about, as the<br />

cell information is permanently updated.<br />

• For compatibility with earlier products and to support legacy applications, any input character may be used to<br />

stop the output in certain cases (depending on the settings of <strong>AT</strong>+IPR and <strong>AT</strong>+CMUX).<br />

8.10.1 <strong>AT</strong>^MONP responses<br />

Response of <strong>AT</strong>^MONP (Example):<br />

<strong>TC63i</strong>_<strong>AT</strong>C_V01.100 Page 213 of 547 11/10/08<br />

Confidential / Released

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!