19.5 <strong>AT</strong>^SCTM<br />

Examples<br />

EXAMPLE 1<br />

URCs issued when the operating temperature is out of range:<br />

^SCTM_A: 1<br />

Caution: Battery close to overtemperature limit.<br />

^SCTM_A: 2<br />

Alert: Battery above overtemperature limit. Engine switches off.<br />

^SCTM_B: 1<br />

Caution: Module close to overtemperature limit.<br />

^SCTM_B: 2<br />

Alert: Module is above overtemperature limit and switches off.<br />

^SCTM_A: -1<br />

Caution: Battery close to undertemperature limit.<br />

^SCTM_A: -2<br />

Alert: Battery below undertemperature limit. Engine switches off.<br />

^SCTM_B: -1<br />

Caution: Module close to undertemperature limit.<br />

^SCTM_B: -2<br />

Alert: Module is below undertemperature limit and switches off.<br />

EXAMPLE 2<br />

URCs issued when the temperature is back to normal (URC is output once):<br />

^SCTM_A: 0<br />

Battery temperature back to normal temperature.<br />

^SCTM_B: 0<br />

Module back to normal temperature.<br />

19.5.1 Deferred shutdown<br />

In the following cases, automatic shutdown will be deferred if a critical temperature limit is exceeded:<br />

• while an emergency call is in progress<br />

• during a two minute guard period after powerup. This guard period has been introduced in order to allow for<br />

the user to make an emergency call. The start of any one of these calls extends the guard period until the end<br />

of the call. Any other network activity may be terminated by shutdown upon expiry of the guard time.<br />

While in a "deferred shutdown" situation, the engine continues to measure the temperature and to deliver alert<br />

messages, but deactivates the shutdown functionality. Once the guard period is expired or the call is terminated,<br />

full temperature control will be resumed. If the temperature is still out of range, ME switches off immediately (without<br />

another alert message).<br />

CAUTION! Automatic shutdown is a safety feature intended to prevent damage to the module. Extended usage<br />

of the deferred shutdown facilities provided may result in damage to the module, and possibly other severe consequences.<br />

<strong>TC63i</strong>_<strong>AT</strong>C_V01.100 Page 495 of 547 11/10/08<br />