28.04.2015 Views

TC63i AT Command Set

TC63i AT Command Set

TC63i AT Command Set

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>TC63i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

<br />

5.3 <strong>AT</strong>^SPIC<br />

5.3 <strong>AT</strong>^SPIC Display PIN counter<br />

The <strong>AT</strong>^SPIC command can be used to find out whether the ME is waiting for a password and, if so, how many<br />

attempts are left to enter the password.<br />

The execute command returns the number of attempts still available for entering the currently required password,<br />

for example the PIN, PUK, PH-SIM PUK etc.<br />

The read command <strong>AT</strong>^SPIC? indicates which password the number of attempts stated by the execute command<br />

actually refers to. Also, the write command may be used to query the counter for a specific password: It<br />

indicates the number of attempts still available for entering the password identified by , for example<br />

the PIN, PIN2, PH-SIM PIN etc.<br />

To check whether or not you need to enter a password use the read commands <strong>AT</strong>+CPIN?, <strong>AT</strong>+CPIN2? and<br />

<strong>AT</strong>^SPIC?. If the response to <strong>AT</strong>+CPIN? is "READY" the counter of the execute command <strong>AT</strong>^SPIC relates to<br />

PIN2. See last example. If the responses to <strong>AT</strong>+CPIN? and <strong>AT</strong>+CPIN2? both read "READY", no password is<br />

currently required, and the referrer of the execute command <strong>AT</strong>^SPIC is explicitly undefined.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^SPIC=?<br />

Response(s)<br />

OK<br />

Read <strong>Command</strong><br />

<strong>AT</strong>^SPIC?<br />

Response(s)<br />

^SPIC: <br />

OK<br />

Exec <strong>Command</strong><br />

<strong>AT</strong>^SPIC<br />

Response(s)<br />

^SPIC: <br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>^SPIC=<br />

Response(s)<br />

^SPIC: <br />

OK<br />

ERROR<br />

+CME ERROR: <br />

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

- + + + + + + - + -<br />

Parameter Description<br />

(num)<br />

Number of attempts left to enter the currently required password. This number will be counted down after each<br />

failure.<br />

<strong>TC63i</strong>_<strong>AT</strong>C_V01.100 Page 129 of 547 11/10/08<br />