15.3 Related <strong>AT</strong> <strong>Command</strong>s<br />

• After installing the USB Bluetooth dongle and the "PlugFree" driver software, the Bluetooth profiles are accessible<br />

via their own virtual COM port.<br />

• If the WinMux driver has been installed another three virtual channels (mapped to additional COM ports) are<br />

available. The physical Multiplexer COM port is connected to the <strong>TC63i</strong>.<br />

• Start the Bluetooth connection using the driver provided by the USB Bluetooth dongle.<br />

• Through "ComBridge", one virtual COM port supplied by "WinMux" is connected to the SAP COM port of<br />

"PlugFree". This establishes a direct communication link between the <strong>TC63i</strong> and the other mobile. However,<br />

take into account that <strong>AT</strong> commands can still be entered on the remaining multiplexer channels of the <strong>TC63i</strong>.<br />

• Select the "ComBridge" SAP filter.<br />

• Press the "ComBridge-Start" button to connect both mobiles.<br />

• Start the SAP client using the <strong>AT</strong> command "<strong>AT</strong>^SRSA=2,2,3,1", if multiplexer channel 3 is used.<br />

15.3.3 Serial Interface Scenario (XSAP)<br />

This example describes the connection of two mobiles. It is recommended that the instructions be followed in the<br />

order that they are presented:<br />

• Install two WinMux drivers on the PC and connect each ME to the physical port of a Multiplexer.<br />

• Connect the PC application "ComBridge" to one virtual COM port of each Multiplexer. This establishes a communication<br />

link between the two mobiles. Bear in mind that <strong>AT</strong> commands can still be issued on both mobiles<br />

using the remaining serial channels.<br />

• Select the "ComBridge" XSAP filter.<br />

• Open the XSAP "Config Filter" menu and deactivate the "Startup - Send Initialization" and the "Shutdown -<br />

Switch back to local SIM" tags. However, the appropriate device IDs need to be entered in the "Startup"<br />

frame.<br />

• Press the "ComBridge - start" button to connect both MEs.<br />

• Start the SAP client via <strong>AT</strong> command "<strong>AT</strong>^SRSA=2,2,3,0", if multiplexer channel 3 is used.<br />

• Start the SAP server via <strong>AT</strong> command "<strong>AT</strong>^SRSA=1,1,3,0", if multiplexer channel 3 is used.<br />