<strong>Condit</strong> <strong>Dam</strong> Hydroelectric Project<br />
Final Supplemental EIS<br />
Based on the project description and management plans provided by PacifiCorp, URS<br />
assembled an inventory of operations and equipment that would generate noise during each<br />
phase of construction. Table 4.8-2 summarizes the operations associated with the Proposed<br />
Action, and the types and numbers of equipment that are expected to be operating during<br />
each phase of work. Reference noise emission data for blasting and each piece of equipment<br />
(compiled during previous construction noise assessments conducted by URS for similar<br />
projects) are also summarized in Table 4.8-2. For the purposes of this assessment, each piece<br />
of equipment was assumed to operate continuously during daytime hours (defined by<br />
Skamania County and Ecology as 7:00 am to 10:00 pm), Monday through Friday. Predictive<br />
noise modeling and potential noise impacts for each activity related to the Proposed Action<br />
are described in the following sections.<br />
Table 4.8-2<br />
Anticipated Noise Sources<br />
Action<br />
Pre-<strong>Dam</strong> <strong>Removal</strong> Activities<br />
Hardware <strong>Removal</strong> & Tunneling<br />
<strong>Dam</strong> Breaching & <strong>Removal</strong><br />
Concrete <strong>Dam</strong> Demolition<br />
Concrete <strong>Removal</strong>, Storage, Disposal<br />
Coffer <strong>Dam</strong> <strong>Removal</strong><br />
Wood Stave Pipeline <strong>Removal</strong> &<br />
Disposal<br />
Concrete Surge Tank <strong>Removal</strong> &<br />
Disposal<br />
Power Facilities <strong>Removal</strong> & Disposal<br />
Sources<br />
Reference<br />
Noise Level<br />
Reference<br />
Distance<br />
Number<br />
On Site<br />
Blasting 122 dBPeak a ¼ mile c NA<br />
Drill rig 74 dBA b 200 feet 1<br />
Rough terrain crane 88 dBA 50 feet 1<br />
Barge-mounted clamshell crane 88 dBA 50 feet 1<br />
Loader 85 dBA 50 feet 2<br />
Excavator 82 dBA 50 feet 2<br />
Dozer 85 dBA 50 feet 2<br />
Truck 88 dBA 50 feet 10<br />
Pickup 72 dBA 50 feet 2<br />
Blasting 122 dBPeak NA NA<br />
Crane 88 dBA 50 feet 1<br />
Loader 85 dBA 50 feet 2<br />
Dozer 85 dBA 50 feet 2<br />
Truck 88 dBA 50 feet 10<br />
Pickup 72 dBA 50 feet 2<br />
Crane 88 dBA 50 feet 1<br />
Loader 85 dBA 50 feet 2<br />
Excavator 82 dBA 50 feet 2<br />
Scraper 89 dBA 50 feet 2<br />
Dozer 85 dBA 50 feet 2<br />
Truck 88 dBA 50 feet 10<br />
Pickup 72 dBA 50 feet 2<br />
Blasting 122 dBPeak NA NA<br />
Crane 88 dBA 50 feet 1<br />
Loader 85 dBA 50 feet 2<br />
Dozer 85 dBA 50 feet 2<br />
Truck 88 dBA 50 feet 10<br />
Pickup 72 dBA 50 feet 2<br />
Loader 85 dBA 50 feet 2<br />
Truck 88 dBA 50 feet 10<br />
Pickup 72 dBA 50 feet 2<br />
Blasting 122 dBPeak NA NA<br />
Drill rig 74 dBA 200 feet 1<br />
Loader 85 dBA 50 feet 2<br />
Excavator 82 dBA 50 feet 2<br />
Scraper 89 dBA 50 feet 2<br />
Truck 88 dBA 50 feet 10<br />
Pickup 72 dBA 50 feet 2<br />
Loader 85 dBA 50 feet 1<br />
Dozer 85 dBA 50 feet 10<br />
Pickup 72 dBA 50 feet 2<br />
4.8-4