A<br />
Contactors<br />
> Heavy duty contactors for demanding applications<br />
> Electronically controlled magnet systems dramatically reduce<br />
pick-up and seal-in, while increasing control voltage tolerance<br />
> Direct connection to PLCs and low level input devices<br />
> Large HP devices (from DIL M580) are vacuum contactors, which<br />
increase electrical lifespan and decrease space requirements<br />
> Built-in suppressor circuit for control protection<br />
Three-pole Contactors <strong>with</strong> AC or DC Electronic Coil (185 to 1000 Amps) ➊<br />
General Use<br />
(A)<br />
Maximum UL / CSA<br />
Horsepower Ratings<br />
Three Phase<br />
Auxiliary<br />
Contacts<br />
Open Enclosed 200 V 230 V 460 V 575 V NO NC<br />
Catalog Number Price<br />
225 202 50 60 125 150 2 2 DILM185/22◆ 1800<br />
250 225 60 75 150 200 2 2 DILM225/22◆ 2200<br />
350 315 75 100 200 250 2 2 DILM250/22◆ 2800<br />
350 315 100 125 250 300 2 2 DILM300/22◆ 3100<br />
450 405 100 150 300 400 2 2 DILM400/22◆ 3900<br />
550 495 150 200 400 500 2 2 DILM500/22◆ 5800<br />
630 567 200 200 400 600 2 2 DILM580/22◆ ➋ 7400<br />
700 630 200 250 500 600 2 2 DILM650/22◆ ➋ 7900<br />
800 720 250 300 600 700 2 2 DILM750/22◆ ➋ 9100<br />
850 765 290 350 700 860 2 2 DILM820/22◆ ➋ 10100<br />
1000 900 – 400 800 1000 2 2 DILM1000/22◆ ➋ 11700<br />
AC & DC Coil Codes ➍<br />
Complete catalog<br />
number (◆) <strong>with</strong>… Voltage<br />
(RDC48)<br />
24 – 48V DC<br />
(only for DILM185 – 500)<br />
(RA110)<br />
48 – 110V AC<br />
48 – 110V DC<br />
(RA250)<br />
110 – 250V AC<br />
110 – 250V DC<br />
(RAC500) 250 – 500V AC<br />
Ordering Instructions<br />
1<br />
Locate the<br />
desired<br />
contactor<br />
2<br />
Complete<br />
catalog<br />
number by<br />
adding coil<br />
code<br />
3<br />
See pages<br />
A17 - A30 for<br />
auxiliaries &<br />
accessories<br />
4<br />
See page<br />
A29 for<br />
terminal lug<br />
selections<br />
Electronic Coil - Application Notes<br />
Conventional coil connection<br />
A1/A2 are applied to voltage in the usual manner.<br />
Direct from the PLC<br />
A 24 V output from the PLC can be connected directly to<br />
connections A3/A4.<br />
From low-consumption command devices<br />
Command devices that can only be subject to minimal<br />
loads such as circuit board relays, control circuit devices<br />
or position switches can be connected directly to<br />
A10/A11.<br />
(+) L1<br />
(–) N<br />
➊ Do not reverse contactors directly.<br />
➋ When operating <strong>with</strong> frequency inverters or when performing a high-voltage test,<br />
the suppressor on the load side must be removed.<br />
➌ Standstill in an emergency (emergency stop).<br />
➍ Wide range electronic coils; all AC coils operate between 40Hz and 60Hz.<br />
A10 moellerNA.com Discount Schedule A20<br />
STARTER-CAT-USA-1206<br />
(+) L1<br />
(–) N<br />
(+) L1<br />
(–) N<br />
A10<br />
A11<br />
24 V<br />
GND<br />
For Immediate Delivery call KM<strong>Parts</strong>.com at (866) 595-9616<br />
Contactors (185 to 1000 amps)<br />
A10<br />
A11<br />
A2<br />
A1<br />
A3<br />
A4<br />
A2<br />
A1<br />
A3<br />
A4<br />
A10<br />
A11<br />
A2<br />
A1<br />
A3<br />
A4<br />
➌<br />
➌<br />
AC & DC Coil<br />
➌