Control Relays DILA DILA-XHI DILER …(D)DILE<br />

Magnet Systems<br />

Pick-up and drop-out values<br />

AC operated<br />

Single-voltage coil 50 Hz and dual-voltage coil Pick-up<br />

50 Hz, 60 Hz<br />

Dual-frequency coil 50/60 Hz Pick-up<br />

DC operated ➊<br />

Pick-up voltage Pick-up<br />

At 24 V: <strong>with</strong>out auxiliary contact module (40 °C) Pick-up<br />

Power consumption<br />

Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Pick-up<br />

Pick-up<br />

Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Sealing<br />

Sealing<br />

Dual-frequency coil 50/60 Hz at 50 Hz Pick-up<br />

Pick-up<br />

Dual-frequency coil 50/60 Hz at 50 Hz Sealing<br />

Sealing<br />

Dual-frequency coil 50/60 Hz at 60 Hz Pick-up<br />

Pick-up<br />

Dual-frequency coil 50/60 Hz at 60 Hz Sealing<br />

Sealing<br />

DC operated Pull-in =<br />

Sealing<br />

[x Uc]<br />

[x Uc]<br />

[x Uc]<br />

[x Uc]<br />

0.8 – 1.1<br />

0.8 – 1.1<br />

0.8 – 1.1<br />

0.7 – 1.3<br />

STARTER-CAT-USA-1206 moellerNA.com C17<br />

–<br />

–<br />

–<br />

–<br />

0.8 – 1.1<br />

0.85 – 1.1<br />

0.85 – 1.3<br />

0.7 – 1.3<br />

[VA]<br />

24<br />

–<br />

25<br />

–<br />

[W]<br />

19<br />

–<br />

22<br />

–<br />

[VA]<br />

3.4<br />

–<br />

4.6<br />

–<br />

[W]<br />

1.2<br />

–<br />

1.3<br />

–<br />

[VA]<br />

27<br />

–<br />

30<br />

–<br />

[W]<br />

22<br />

–<br />

26<br />

–<br />

[VA]<br />

4.2<br />

–<br />

5.4<br />

–<br />

[W]<br />

1.4<br />

–<br />

1.6<br />

–<br />

[VA]<br />

25<br />

–<br />

29<br />

–<br />

[W]<br />

25<br />

–<br />

24<br />

–<br />

[VA]<br />

3.3<br />

–<br />

3.9<br />

–<br />

[W]<br />

1.2<br />

–<br />

1.1<br />

–<br />

[W] 3 – 2.6 –<br />

Duty factor [% DF] 100 – 100 –<br />

Switching times at 100 % Uc (approximate values)<br />

AC operated closing delay<br />

AC operated make contact opening delay<br />

AC operated <strong>with</strong> auxiliary contact module, max. closing delay<br />

DC operated closing delay<br />

DC operated, make contact opening delay<br />

DC operated <strong>with</strong> auxiliary contact module, max. closing delay<br />

[ms]<br />

[ms]<br />

[ms]<br />

[ms]<br />

[ms]<br />

[ms]<br />

➊ Pure DC voltage or three-phase bridge rectifier or full wave rectifier <strong>with</strong> smoothing<br />

capacitor (or filter).<br />

≤ 21<br />

≤ 18<br />

–<br />

≤ 31<br />

≤ 12<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

14 – 21<br />

8 – 18<br />

45<br />

26 – 35<br />

15 – 25<br />

70<br />

For Immediate Delivery call KM<strong>Parts</strong>.com at (866) 595-9616<br />

Technical Data<br />

DIL A & DIL ER Control Relays<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

45<br />

–<br />

–<br />

70<br />

C<br />

Control Relays

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!