C<br />
Control Relays<br />
> Six and eight-pole relays available by adding snap-on auxiliary<br />
contact block<br />
> Positively guided contacts; NO and NC contacts can never be<br />
closed simultaneously<br />
> Share common accessories <strong>with</strong> <strong>Moeller</strong>’s popular DIL M<br />
contactor line<br />
DILA Control Relays <strong>with</strong> AC Coil, 4-pole ➊<br />
Control Relay Schematic<br />
A.C. Coil Codes ➊<br />
Complete catalog<br />
number (u)<br />
<strong>with</strong>…<br />
A1 13 23 33 43<br />
A2 14 24 34 44<br />
A1 13 21 33 43<br />
A2 14 22 34 44<br />
A1 13 21 31 43<br />
A2 14 22 32 44<br />
Voltage Range<br />
50Hz 60Hz<br />
(24V60Hz) – 24V<br />
(48V60Hz) 42V 48V<br />
(120V60Hz) 110V 120V<br />
(208V60Hz) – 208V<br />
(240V60Hz) 230V 240V<br />
(480V60Hz) 415V 480V<br />
(600V60Hz) – 600V<br />
Ordering Instructions<br />
1<br />
Locate the<br />
desired<br />
relay<br />
2<br />
Complete<br />
catalog<br />
number by<br />
adding coil<br />
voltage<br />
3<br />
See pages<br />
C8 - C11 for<br />
auxiliaries &<br />
accessories<br />
Contacts UL/CSA<br />
NO NC<br />
4 0<br />
Pilot<br />
Duty<br />
Rating<br />
General<br />
Purpose (A)<br />
Catalog Number Price<br />
DILA-40u 62<br />
A 600<br />
3 1 10 DILA-31u 62<br />
P 300<br />
2 2 DILA-22u 62<br />
UL/CSA Rating Codes (per UL508 and CSA 22.2 No.14-95)<br />
Control Relays<br />
Series DIL A 4-pole Relays<br />
UL/CSA Continuous<br />
120VAC<br />
Standard Amps<br />
Make Break<br />
Circuit Voltage<br />
240VAC 480VAC<br />
Make Break Make Break<br />
600VAC<br />
Make Break<br />
VA<br />
Make Break<br />
A600 10 60 6 30 3 15 1.5 12 1.2 7200 720<br />
UL/CSA Continuous 125VDC 250VDC 301-600VDC VA<br />
Standard Amps Make Break Make Break Make Break Make Break<br />
P300 5 1.1 1.1 0.55 0.55 – – 138 138<br />
NOTE: This table represents minimum requirements to achieve a rating of A600/<br />
P300. All <strong>Moeller</strong> relays meet or exceed these standards.<br />
➊ Other coil voltages between 12 and 600VAC available by special order; Contact<br />
your <strong>Moeller</strong> representative for information.<br />
C4 moellerNA.com Discount Schedule A20<br />
STARTER-CAT-USA-1206<br />
For Immediate Delivery call KM<strong>Parts</strong>.com at (866) 595-9616