18.11.2012 Views

Start with Moeller - Klockner Moeller Parts

Start with Moeller - Klockner Moeller Parts

Start with Moeller - Klockner Moeller Parts

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A<br />

Contactors<br />

DILM185 – DILM1000 Contactors DILM185 DILM225 DILM250 DILM300<br />

General<br />

Standards UL, CSA, IEC/EN60947, VDE 0660<br />

Lifespan, mechanical<br />

AC operated Ops<br />

DC operated Ops<br />

Max. Operating frequency, mechanical<br />

AC operated<br />

DC operated<br />

Climatic proofing<br />

Open<br />

Enclosed<br />

[x 10 6 ]<br />

[x 10 6 ]<br />

Ops/h<br />

Ops/h<br />

Ambient temperature<br />

Open [C]<br />

[F]<br />

Enclosed [C]<br />

[F]<br />

Storage [C]<br />

[F]<br />

Mounting position<br />

AC and DC<br />

Mechanical shock resistance (IEC/EN 60068-2-27)<br />

Half-sinusoidal shock, 10 ms<br />

Main Contacts NO contacts Make<br />

NO/NC contacts Make/Break<br />

Auxillary contacts NO contacts Make<br />

NC contacts Break<br />

[g]<br />

[g]<br />

[g]<br />

[g]<br />

10<br />

10<br />

3000<br />

3000<br />

-25 °C…60 °C<br />

-13 °F…140 °F<br />

-25 °C…40 °C<br />

-13 °F…104 °F<br />

-40 °C…80 °C<br />

-40 °F…176 °F<br />

10<br />

–<br />

10<br />

8<br />

A52 moellerNA.com STARTER-CAT-USA-1206<br />

10<br />

10<br />

3000<br />

3000<br />

10<br />

10<br />

3000<br />

3000<br />

Damp heat constant to IEC60068-2-78<br />

Damp heat, cyclic to IEC 60068-2-30<br />

-25 °C…60 °C<br />

-13 °F…140 °F<br />

-25 °C…40 °C<br />

-13 °F…104 °F<br />

-40 °C…80 °C<br />

-40 °F…176 °F<br />

180°<br />

90°<br />

10<br />

–<br />

10<br />

8<br />

90°<br />

-25 °C…60 °C<br />

-13 °F…140 °F<br />

-25 °C…40 °C<br />

-13 °F…104 °F<br />

-40 °C…80 °C<br />

-40 °F…176 °F<br />

30°<br />

30°<br />

10<br />

–<br />

10<br />

8<br />

7<br />

7<br />

2000<br />

2000<br />

-25 °C…60 °C<br />

-13 °F…140 °F<br />

-25 °C…40 °C<br />

-13 °F…104 °F<br />

-40 °C…80 °C<br />

-40 °F…176 °F<br />

Degree of protection IP00 IP00 IP00 IP00<br />

Protection against direct contact when actuated from front (IEC536)<br />

Weight<br />

Finger and-back-of-hand proof<br />

AC<br />

[kg]<br />

6.5<br />

6.5<br />

6.5<br />

8<br />

DC<br />

[kg]<br />

6.5<br />

6.5<br />

6.5<br />

8<br />

Main terminals DILM225-XKU-S DILM225-XKU-S DILM400-XKU-S DILM400-XKU-S<br />

Wire Capacity minimum [AWG] 6 AWG<br />

6 AWG<br />

4 AWG<br />

4 AWG<br />

(single or double) (single or double) (single or double) (single or double)<br />

(Cu cable) maximum [AWG] 350 MCM<br />

350 MCM<br />

600 MCM<br />

600 MCM<br />

Main cable cross sections<br />

(2 x 300 MCM) (2 x 300 MCM) (2 x 500 MCM) (2 x 500 MCM)<br />

Solid [mm2 ] – – – –<br />

Flexible <strong>with</strong> ferrule [mm2 ] – – – –<br />

Flexible <strong>with</strong> cable lug [mm2 ] 35-95 50-240 50-240 50-240<br />

Stranded [mm2 ] – – – –<br />

Stranded <strong>with</strong> cable lug [mm2 ] 50-120 70-240 70-240 70-240<br />

Flat conductor<br />

[mm] – – – –<br />

Number of segments x width x thickness<br />

Bus bar Width [mm] 20 20 25 25<br />

Main cable connection screw/bolt M10 M10 M10 M10<br />

Tightening torque<br />

Control circuit cable cross sections<br />

[Nm] 24 24 24 24<br />

Solid [mm2 ] 1 x (0.75-25)<br />

1 x (0.75-25)<br />

1 x (0.75-25)<br />

1 x (0.75-25)<br />

2 x (0.75-2.5)<br />

2 x (0.75-2.5)<br />

2 x (0.75-2.5)<br />

2 x (0.75-2.5)<br />

Flexible <strong>with</strong> ferrule [mm2 ] 1 x (0.75-25)<br />

1 x (0.75-25)<br />

1 x (0.75-25)<br />

1 x (0.75-25)<br />

2 x (0.75-2.5)<br />

2 x (0.75-2.5)<br />

2 x (0.75-2.5)<br />

2 x (0.75-2.5)<br />

Solid or stranded [AWG] 2 x (18-12) 2 x (18-12) 2 x (18-12) 2 x (18-12)<br />

Control circuit cable connection screw/bolt M3.5 M3.5 M3.5 M3.5<br />

Tightening torque [Nm] 1.2 1.2 1.2 1.2<br />

For Immediate Delivery call KM<strong>Parts</strong>.com at (866) 595-9616<br />

Technical Data<br />

DIL M185 to DIL M1000 Contactors<br />

10<br />

–<br />

10<br />

8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!