18.11.2012 Views

Start with Moeller - Klockner Moeller Parts

Start with Moeller - Klockner Moeller Parts

Start with Moeller - Klockner Moeller Parts

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Electronic Overload Relay ZEV<br />

General<br />

Standards IEC/EN 60947, VDE<br />

0660, UL, CSA<br />

Climatic proofing<br />

Ambient temperature<br />

Damp heat, constant,<br />

to IEC 60068-2-78;<br />

Damp heat, cyclic, to<br />

IEC 60068-2-30<br />

Open ➊ [°C] -25…60 °C<br />

[°F] -13…140 °F<br />

Enclosed ➊ [°C] -25…40 °C<br />

[°F] -13…104 °F<br />

Storage [°C] -40…80 °C<br />

[°F] -40…176 °F<br />

Temperature compensation Continuous<br />

Mounting position As required<br />

Weight [kg] 0.20<br />

Mechanical shock resistance half-sinusoidal shock 10ms [g] 15<br />

Degree of protection IP20<br />

Protection against direct contact when actuated from front<br />

Main Contacts<br />

Finger and back-ofhand<br />

proof<br />

Overload relay setting range [A] 1 – 820 ➋<br />

Short-circuit protection rating maximum fuse With overload relay in<br />

conjunction <strong>with</strong> a<br />

transformer as<br />

required<br />

for the contactor<br />

Terminal screw M3.5<br />

Tightening torque [Nm] 0.8<br />

Tools<br />

Pozidriv screwdriver<br />

Standard screwdriver<br />

Auxiliary and control circuit connections<br />

[Size]<br />

[mm]<br />

1<br />

0.8 x 5.5<br />

Rated impulse <strong>with</strong>stand voltage Uimp [V] 4000<br />

Overvoltage category / pollution degree III/3<br />

Terminal capacity<br />

Solid [mm 2 ] 1 x (0.5 – 2.5)<br />

2 x (0.5 – 1.5) ➌<br />

Flexible <strong>with</strong> ferrule [mm 2 ] 1 x (0.5 – 2.5)<br />

2 x (0.5 – 1.5) ➌<br />

Solid or stranded [AWG] 1 x (18 – 14)<br />

Terminal screw M3.5<br />

Tightening torque [Nm] 0.8<br />

Tools<br />

Pozidriv screwdriver<br />

Standard screwdriver<br />

[Size]<br />

[mm]<br />

1<br />

0.8 x 5.5<br />

➊ Limited readability of the LCD display at < -15 °C (5 °F).<br />

➋ Setting range dependant on current sensor.<br />

➌ Only the following combinations are permissible: 0.5 and 0.75mm 2 , 0.75 and 1<br />

mm 2 , 1 and 1.5 mm 2 .<br />

Technical Data<br />

Electronic Overload Relays<br />

Electronic Overload Relay ZEV<br />

Auxiliary and control circuit connections (continued)<br />

Auxiliary circuit rated insulation voltage Ui [V AC] 250<br />

Rated operational voltage Ue [V AC] 240<br />

Safe isolation to VDE 0106 Part 101 and Part 101/A1<br />

Between the auxiliary contacts [V AC] 240 ➍<br />

Conventional thermal current Ith [A] 6<br />

Rated operational current<br />

AC-15<br />

Make contact 120 V Ie<br />

240 V Ie<br />

415 V Ie<br />

500 V Ie<br />

Break contact 120 V Ie<br />

240 V Ie<br />

415 V Ie<br />

500 V Ie<br />

DC-13 L/R ≤ 15 ms ➏<br />

24 V Ie<br />

60 V Ie<br />

110 V Ie<br />

220 V Ie<br />

➍ Up to 240 V depending on contact assignment between main supply voltage and<br />

outputs. No potential isolation to thermistor, core balance transformer or the current<br />

sensor.<br />

➎ Auxiliary contacts are 1.5 A.<br />

➏ Making and breaking conditions to DC-13, L/R constant as stated.<br />

STARTER-CAT-USA-1206 moellerNA.com B23<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

[A]<br />

3 ➎<br />

3 ➎<br />

–<br />

–<br />

3<br />

3<br />

–<br />

–<br />

Power consumption P max. [W] 2.5<br />

Short-circuit rating <strong>with</strong>out welding<br />

Max. fuse [A gG/gL] 6<br />

Pick-up and drop-out values<br />

AC operated<br />

DC operated<br />

UL / CSA<br />

[x Uc]<br />

[x Uc]<br />

1<br />

–<br />

–<br />

–<br />

0.85 – 1.1<br />

0.85 – 1.1<br />

Rated Voltage [V AC/DC] 600 / 300<br />

Pilot Duty [AC] B600 Same polarity<br />

B300 Opposite polarity<br />

Thermistor Protection<br />

[DC]<br />

R300<br />

Total resistance (cold) [Ω] 1500<br />

Response value [Ω] 2720 – 3680<br />

Reset range [Ω] 1500 – 1650<br />

Recovery time<br />

Overload<br />

Thermistor tripping<br />

Ground-fault protection<br />

For Immediate Delivery call KM<strong>Parts</strong>.com at (866) 595-9616<br />

See page B22<br />

5 °C under response<br />

temperature<br />

Immediate<br />

B<br />

Motor Protection

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!