Start with Moeller - Klockner Moeller Parts
Start with Moeller - Klockner Moeller Parts
Start with Moeller - Klockner Moeller Parts
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
DIL M Low Range<br />
<strong>Moeller</strong>’s DIL M contactor series includes a completely<br />
NEW offering in the lower 7 to 150A range. Consisting<br />
of four frame sizes, this range is the newest and most<br />
modern of any control manufacturer!<br />
Compact<br />
design for BOTH<br />
currents<br />
Conventional contactors<br />
designed for DC control<br />
applications can be up<br />
to 30% larger than their<br />
AC counterparts. Not<br />
anymore! Unique to <strong>Moeller</strong>’s DIL M contactors, AC and<br />
DC units are the same frame size throughout the entire<br />
range. The reduced size means smaller DC panels than<br />
ever before. This also means you can now design one<br />
panel for either AC or DC control, <strong>with</strong>out having to plan<br />
for a larger DC contactor.<br />
Easy to assemble<br />
Coil terminals are located on the front of the new contactors<br />
to simplify wiring. Both<br />
two and four-pole auxiliary contacts<br />
snap on <strong>with</strong>out tools. Units<br />
40A and above accept both side<br />
and top mount auxiliaries for increased<br />
flexibility. In addition, devices up to 32A include<br />
built-in auxiliary contacts for increased economy <strong>with</strong><br />
no additional space requirement.<br />
Contacts designed for safety<br />
Auxiliary contact blocks for new DIL M contactors have<br />
positively guided contacts for added safety in control<br />
circuits. Positively guided auxiliary contacts insure that,<br />
throughout the life of the contactor, NO and NC contacts<br />
will never close simultaneously…even if a contact<br />
welds. In addition, DIL M contactors to 65A have “mirror”<br />
contacts, which ensure that all auxiliary contacts<br />
(whether built-in or add-on) function correctly in relation<br />
to the power contacts.<br />
Special advantages of going DC<br />
In addition to sharing the same frame size as AC contactors,<br />
DC units of 17A and above also feature electronic<br />
drives that dramatically reduce pick-up and sealing consumption.<br />
These drives produce several benefits:<br />
• less heat is generated, eliminating the<br />
need for a fan<br />
• smaller control transformers are required<br />
• contactors up to DIL M32 can be directly<br />
actuated from PLCs, eliminating the need for<br />
a coupling relay<br />
These benefits lower your cost by consuming less power,<br />
eliminating additional components, and permitting<br />
higher packing density in the panel.<br />
DC units to 150A also carry a built-in high-speed suppressor<br />
circuit, eliminating the need for purchasing and<br />
installing a separate external suppressor. Again, lower<br />
total cost and smaller panel space result.<br />
For additional safety and convenience, <strong>Moeller</strong>’s DIL M<br />
DC contactors feature an expanded voltage tolerance,<br />
beyond that specified by IEC/EN 60947. This accommodates<br />
a range of -30% to +20% for DIL M contactors<br />
17A and above. It is one of the largest voltage tolerance<br />
ranges of any control manufacturer.<br />
For Immediate Delivery call KM<strong>Parts</strong>.com at (866) 595-9616<br />
+20%<br />
-30%<br />
A3<br />
A<br />
Contactors