Injection non-cracked concrete with FIS A<br />

Chemical fixings<br />

LOADS<br />

Injection system FIS VT with threaded rod FIS A C (material 1.4529)<br />

Highest permissible loads for a single anchor 1) 6) in concrete C20/25 4)<br />

For the design the complete approval ETA - 08/0061 has to be considered.<br />

Non-cracked concrete<br />

Type<br />

Minimum effective<br />

anchorage depth<br />

Maximum effective<br />

anchorage depth<br />

Minimum member<br />

thickness<br />

Installation<br />

torque<br />

Permissible<br />

tensile load<br />

Permissible<br />

shear load<br />

Min.<br />

spacing<br />

Min.<br />

edge distance<br />

h ef,min h ef,max h min T inst<br />

3)<br />

N perm<br />

3)<br />

V perm<br />

2)<br />

s min<br />

2)<br />

c min<br />

FIS A M8 C<br />

FIS A M10 C<br />

FIS A M12 C<br />

FIS A M16 C<br />

FIS A M20 C<br />

FIS A M24 C<br />

FIS A M30 C<br />

[mm] [mm] [mm] [Nm] [kN] [kN] [mm] [mm]<br />

64 100 10,0 6,1 7,4 40 40<br />

96 130 10,0 9,1 7,4 40 40<br />

80 110 20,0 9,5 11,4 45 45<br />

120 150 20,0 14,2 11,4 45 45<br />

96 130 40,0 13,6 17,1 55 55<br />

144 180 40,0 20,5 17,1 55 55<br />

125 160 60,0 21,2 31,4 65 65<br />

192 230 60,0 32,6 31,4 65 65<br />

160 210 120,0 31,9 49,1 85 85<br />

240 290 120,0 47,9 49,1 85 85<br />

192 250 150,0 43,1 70,3 105 105<br />

288 345 150,0 64,6 70,3 105 105<br />

240 310 300,0 62,8 112,0 140 140<br />

360 430 300,0 94,2 112,0 140 140<br />

1)<br />

The partial safety factors for material resistance as regulated in the approval as well as a partial<br />

safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor<br />

with a spacing s ≥ 3 x h ef and an edge distance c ≥ 1,5 x h ef . Accurate data see approval.<br />

2)<br />

Minimum possible axial spacings resp. edge distance while reducing the permissible load.<br />

3)<br />

For combinations of tensile loads, shear loads, bending moments as well as reduced edge<br />

distances or spacings (anchor groups) see approval.<br />

4)<br />

For higher concrete strength classes up to C50/60 higher permissible loads may be possible.<br />

6)<br />

The given loads are valid for fixations in dry and humid concrete for temperatures in the substrate<br />

up to +50°C (resp. short term up to 80°C) and best possible drillhole cleaning according approval.<br />