Frame fixing SXR<br />

LOADS<br />

Frame fixing SXR 4)<br />

Highest permissible loads 1) for a single anchor for multiple fixings of facades in normal concrete ≥ C12/15 resp. ≥ B15.<br />

For the design the complete approval Z-21.2-1862 has to be considered.<br />

Cracked or Non-cracked concrete<br />

Type Min. embedment depth Min. member thickness Permissible load Min. spacing Min. edge distance<br />

h nom (h v ) h (d) F perm<br />

3)<br />

s min (a) 2) c min (a r ) 2)<br />

[mm] [mm] [kN] [mm] [mm]<br />

SXR 8 50 100 0,5 100 50<br />

SXR 10 50 100 1,6 100 50<br />

1)<br />

The required safety factors as regulated in the approval are considered.<br />

2)<br />

Minimum possible axial spacings resp. edge distance while reducing the permissible load.<br />

3)<br />

Valid for tensile load, shear load and oblique load under any angle. Restrictions for permanently<br />

acting tensile loads see approval. For combinations of tensile loads, shear loads, bending<br />

moments see approval table 4.<br />

LOADS<br />

Type<br />

4)<br />

gvz and A4. For exterior applications of galvanised screws measures against incoming humidity<br />

have to be taken.<br />

Frame fixing SXR 4)<br />

Highest permissible loads 1) for a single anchor for multiple fixings of non-structural applications in normal concrete ≥ C12/15 resp. ≥<br />

B15. For the design the complete approval ETA-07/0121 has to be considered.<br />

Cracked or Non-cracked concrete<br />

Min.<br />

Min.<br />

Permissible<br />

Permissible<br />

Min. spacing Min. edge distance<br />

embedment depth member thickness tensile load<br />

shear load<br />

h nom (h v ) h min<br />

6)<br />

N perm<br />

6)<br />

V perm<br />

2)<br />

s min<br />

2)<br />

c min<br />

[mm] [mm] [kN] [mm] [mm]<br />

SXR 8 50 100 1,0 4,2 (3,4) 5) 50 50<br />

SXR 10 50 100 1,8 5,4 (5,0) 5) 50 100<br />

1)<br />

The required partial safety factors for material resistance as well as a partial safety factor for<br />

load actions of L = 1,4 are considered.<br />

2)<br />

Minimum possible axial spacings resp. edge distance for concrete ≥ C16/20 while reducing the<br />

permissible load.<br />

4)<br />

gvz and A4. For exterior applications measures against incoming humidity have to be taken.<br />

5)<br />

Values in brackets apply for A4-type - stainless steel of the corrosion resistance class III, e.g. A4.<br />

6)<br />

Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C). For long term<br />

temperatures up to 30°C higher permissible loads may be possible.<br />

3)<br />

For combinations of tensile loads, shear loads, bending moments as well as reduced edge<br />

distances or spacings (anchor groups) see approval.<br />

Frame fixings / Stand-off installation<br />

229