Weather facing reconstruction system FWS<br />

INSTALLATION<br />

TECHNICAL DATA<br />

Weather facing reconstruction system FWS<br />

Chemical fixings<br />

Residual core drill FWS-B<br />

Total length Nom. diameter drill bit Effective anchorage depth in Anchors per cartridge Sales unit<br />

the load-bearing skin<br />

FIS V 360 S<br />

l d B h v<br />

Art.-No. DIBt [mm] [mm] [mm] [pcs]<br />

Item<br />

FWS-A 205 062342 ▯ 205 40 80 4 - 5 5<br />

FWS-A 230 062343 ▯ 230 40 80 4 - 5 5<br />

FWS-B 062344 — — — — — 1<br />

Approval<br />

LOADS<br />

Weather facing reconstruction system FWS<br />

Highest permissible shear loads 1) 6) for a single anchor in a load-bearing skin made of concrete ≥ B15 resp. C12/15.<br />

For the design the complete approval Z-21.8-1557 has to be considered.<br />

Type<br />

Effective<br />

anchorage<br />

depth in the<br />

load-bearing skin<br />

Min.<br />

thickness of<br />

load-bearing<br />

layer<br />

Thickness<br />

of thermal<br />

insulation 2)<br />

Thickness of<br />

outer leaf<br />

Permissible<br />

bending moment<br />

Permissible<br />

shear load 1)<br />

Cracked or non-cracked concrete<br />

Min.<br />

spacing 3)<br />

Min.<br />

spacing 3)<br />

h ef (h v ) h t h D h w M perm V perm s min (a h,min ) c min (a r,1 )<br />

[mm] [mm] [mm] [mm] [Nm] [kN] [mm] [mm]<br />

FWS-A-205 4) 80 ≥120 80 40-60 1240,0 8,5 450 300<br />

FWS-A-230 4) 80 ≥120 100 45-60 1240,0 8,1 450 300<br />

1)<br />

Required safety factors are considered. The given loads are valid under the pre-condition that an<br />

4)<br />

The determination of the permissible shear load for special lengths is done according Annex 3 and<br />

additional thermal insulation will be applied on the weather facing.<br />

4 of the approval.<br />

2)<br />

For bigger insulation thicknesses special lengths are possible.<br />

6)<br />

The given loads are valid for fixations in dry and humid concrete for temperatures in the substrate<br />

3)<br />

For exact arrangement of the bolts as well as for eventually needed additional proofs see approval.<br />

up to +50°C (resp. short term up to 80°C) and drillhole cleaning according approval.<br />

145