10.07.2015 Views

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MICRO-SCREEN ® SystemsMetal Box <strong>Co</strong>ntrollersMICRO-SCREEN Muting Metal Box <strong>Co</strong>ntroller Dimensions85.0 mm(3.35")25.4 mm(1.00")25.4 mm(1.00")260.0 mm(10.24")101.4 mm(4.00")25.4 mm(1.00")25.4 mm(1.00")BANNER ENGINEERING CORPORATION9714 10th Ave. No.• Minneapolis, MN 55441 •612-544-3164MODEL NO. USCC-1L2M MICRO-SCREEN ® <strong>Co</strong>ntrol BoxOptical Safety Systems295.0 mm(11.62")273.0 mm(10.75")LIGHTSCREENDIAGNOSTICDISPLAYLIGHT SCREEN INDICATORSSTEADY: FLASHING:BLOCKED LOCKOUTCLEAR BLANKINGRESET ALIGNMENTRATED SUPPLY VOLTAGERATED SUPPLY CURRENTFUSE RATINGRESPONSE TIME (See Manual)ENCLOSURE RATINGTEMPERATURE RATINGFSD1, FSD2, SSD RATINGAUX CONTACTS RATINGBLANKING SETUPPERIODIC CHECK PROCEDUREE-STOP RESPONSE TIMERUN115V ac, 50/60Hz500 mA ac MAX.1.0 A ac, 250V ac48 msUL / CSA TYPE 13, IP640 - 50 C (32 - 122 F)230V ac, 4A Resistive10 VA, 125V ac/dc, 500 mASee Instruction ManualSee Instruction Manual25 msRUNLIGHTSCREENRESETSYSTEMDIAGNOSTICDISPLAYSYSTEM INDICATORSSTEADY: FLASHING:OVERRIDE LOCKOUTOUTPUT ONRESET WAITING FOR RESET230V ac, 50/60Hz250 mA ac MAX.500 mA ac, 250V acSYSTEMRESET24V dc2.5 A dc MAX.Internal ResetableFor use with USE/R... Series Emitters/Receivers and QDU-5..C cablesWARNINGElectrical shock hazard exists when <strong>Co</strong>ntrol Box door is open. Use extreme caution. Access to the <strong>Co</strong>ntrol Box interior to be byqualified service personnel only (see instruction manual).Always disconnect all power from the MICRO-SCREEN System and from the machine before making wire connectionsor before replacing any components.12 x ø7.5 mm (0.30")MICRO-SCREEN Muting Metal Box <strong>Co</strong>ntroller Internal FeaturesTESTabLIGHT SCREEN RESETab+12V dcLIGHT COMSCREEN T / RCONNECTIONST / RDRAINLIGHT SCREEN AUXabSYSTEM AUXab3a 1a3b 1bMUTING DEVICES – –+ +4a 2a4b 2b1a 2aOVERRIDE1b 2baMUTE LAMPbMUTE aSYSTEM RESET b24V dcCOMTB1TB2TB3TB4LightScreen<strong>Co</strong>ntrollerBoardTB5TB6ab MUTE ENABLETB7System<strong>Co</strong>ntrollerBoardRelay PackFuse2a2bPower Select230V acTB10115V acTB11MonitoringTB81a1bTB9aSSDbab FSD 2ab FSD 1LNNote: TB3 Emitter/Receiver <strong>Co</strong>lor <strong>Co</strong>desBrown = +12V dcBlue = COMWhite = T/RBlack = T/RUninsulated = Drain84 Banner <strong>Engineering</strong> <strong>Co</strong>rp. • Minneapolis, MN U.S.A. • bannerengineering.com • Tel: 763.544.3164

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!