10.07.2015 Views

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RMINI-SCREEN ® SystemsMetal Box <strong>Co</strong>ntrollersDiagnostic DisplaysMINI-SCREEN Muting Metal Box <strong>Co</strong>ntroller Specifications (cont’d)Light Screen Diagnostic Display (left window) is a two-digit numeric display that indicates the causeof lockout conditions.<strong>Co</strong>ntrols and AdjustmentsLight Screen andSystem Reset InputsExternal Device Monitoring(EDM) Input(s)Mute Enable InputOverride InputsLight Screen and SystemAux. Monitor Relay OutputsOutput <strong>Co</strong>nfiguration(FSD1, FSD2, SSD)Mute Lamp OutputAuxiliary DC Supply OutputEnclosureOperating <strong>Co</strong>nditionsSystem Diagnostic Display (right window) is a two-digit numeric display that indicates the cause oflockout conditions and the amount of time, in seconds, remaining for the backdoor timer.• Light Screen Key Reset after power-up and light screen lockouts•Selection switches to enable floating blanking• Program switches to enable fixed blanking• Light Screen and System Auto Power-up selection switches• System Key Reset after power-up, system lockouts, and latched conditions• Selection switches for Monitored or Non-Monitored Muting Indicator• Selection switches for One-Way or Two-Way (directional/non-directional) Muting• Selection switches for One-Channel, Two-Channel Monitoring or No Monitoring (EDM)• Selection switches for Backdoor Timer settings and Mute-on-Power-UpTerminals must be closed for a minimum of 0.05 seconds in order to guarantee a reset. Theswitching device must be capable of switching 15-50V dc at 20-100 mA.Two pairs of terminals are provided to monitor the state of external devices that are being controlledby the FSD outputs. The device must be capable of switching 15-50V dc at 20-100 mA.Terminals must be closed in order to start a mute; opening this input after mute has begun has noeffect. The switching device must be capable of switching 15-50V dc at 20-100 mA.The two-channel inputs must be closed within 3 seconds of each other (simultaneity requirement)and held closed during the 10-second Override. To initiate a subsequent Override, open bothchannels, wait 3 seconds, and then re-close both channels (within 3 seconds). The switching devicesmust be capable of switching 15-50V dc at 20-100 mA.Muting Device Input The muting devices work in pairs (M1 and M2, M3 and M4) and are required to be “closed” within 3seconds of each other (simultaneity requirement) to initiate a mute (assuming all other conditions aremet). Each muting device must be capable of switching 15-50V dc at 20-100 mA.<strong>Co</strong>nnectionsReed relay; 125V ac/dc max. at 500 mA max. (10 VA maximum, resistive load)Forced-guided contact relay (resistive load).MSCC-..2: FSD1 & 2, SSD = 250V ac max., 4 amp max.MSCC-..3: FSD1 & 2, CNC = 250V ac max., 6 amp max.;SSD = 250V ac max., 4 amp max.Mechanical life: 10,000,000 operations (minimum).Electrical life: 100,000 operations (typical @ 1.0 kVA switching power).Arc suppression is recommended when switching inductive loads. See Warning on page 336.A monitored or non-monitored (selectable) sinking output. If monitoring has been selected, thecurrent draw must be within 10 mA to 360 mA.Max. Switching Voltage: 30V dcMax. Switching Current: 360 mAMin. Switching Current: 10 mASaturation Voltage: ≤1.5V dc24V dc ± 25%, 500 mA maxSize: See dimensions on next page.Material: Welded steel box with black polyester powder paint finish.Rating: NEMA 13; IEC IP64See page 338 for general hookup information.Temperature: 0° to +50°C (+32° to 122°F)Relative humidity: 95% maximum (non-condensing)Optical Safety SystemsFMEA Tested Per requirements of IEC61496-1 (type 4)ApplicationsCertificationsUse of fixed blanking requires sensors with 16 or more light beams. Up to 12 beams or 30% of thetotal number of beams in the array may be blanked, whichever is less. Call factory for applicationsassistance if a greater number of blanked beams is required.Banner <strong>Engineering</strong> <strong>Co</strong>rp. • Minneapolis, MN U.S.A. • bannerengineering.com • Tel: 763.544.3164119

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!