10.07.2015 Views

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RRMICRO-SCREEN ® SystemsDIN Module <strong>Co</strong>ntrollersMICRO-SCREEN DIN Module <strong>Co</strong>ntrollers SpecificationsSystem Power RequirementsFuse RatingResponse Time24V dc ±15%, 10% maximum ripple, 1.5 amps max.2 amp, 250 V (3 AG or 5 x 20 mm slow blow)Light Screen: Less than 38 ms (all lengths)E-Stop: Less than 15 msStatus Indicators(on control box and receiver)Diagnostic Indicator<strong>Co</strong>ntrols and AdjustmentsEmergency Stop Switch InputRed = BLOCKED Flashing red = LOCKOUTGreen = CLEAR Flashing green = BLANKING ONYellow = RESET Double-flashing yellow = Waiting for Power-up Key ResetSingle-flashing yellow = ALIGNMENT. Flash rate increases with the number of sensing beams“made”, solid yellow when aligned and defined area is clear.Two-digit numeric display indicates cause of lockout condition and total number of beams blockedKeyed Reset of system lockout conditionsFloating Blanking selection switches and Fixed Blanking programming switchesAuto Power-up On-Off switchesEmergency Stop actuator must offer two normally closed contacts and be capable of switching 50 mA@ 30V dc. Total resistance limit of 30 Ω. Functional stop category 0 per NFPA 79 and ISO 13850(EN 418), Safety category 4 per iso 13849-1 (EN 954-1).Simultaneity requirement < 100 msOptical Safety SystemsAUX Non-safety Output <strong>Co</strong>ntactOutput <strong>Co</strong>nfiguration(FSD1, FSD2, and SSD)Enclosure<strong>Co</strong>nnectionsOperating <strong>Co</strong>nditionsReed relay; 125V ac or dc max., 500 mA max. (10 VA maximum, resistive load)Forced-guided contact relay (resistive load).FSD1 & 2, SSD = 250V ac max., 4 amp max.Mechanical life: 10,000,000 operations (minimum).Electrical life: 100,000 operations (typical @1.0 kVA switching power).Arc suppression is recommended when switching inductive loads. See Warning on page 319.Note: <strong>Co</strong>ntrollers with model suffix “2” have two FSD output contacts and those with model suffix “4”have four FSD output contacts.Size: See dimensions on next page.Material: gray polycarbonate, clear polycarbonate cover.Rating: NEMA 1, (IP 20)See pages 322 to 324 for general hookup information.Temperature: 0° to +50°C (+32° to 122°F)Relative humidity: 95% maximum (non-condensing)FMEA Tested Per requirements IEC 61496-1 (Type 4)Application NotesUse of fixed blanking requires sensors with 16 or more light beams. Up to 12 beams or 30% of thetotal number of beams in the array may be blanked, whichever is less. Call factory for applicationsassistance if a greater number of blanked beams is required.CertificationsIEC 61496-1 &2,Type 4Except USDINT-1T2EPresenceSensingDeviceBanner <strong>Engineering</strong> <strong>Co</strong>rp. • Minneapolis, MN U.S.A. • bannerengineering.com • Tel: 763.544.316487

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!