pdf (2140k) - Adcon Engineering Co
pdf (2140k) - Adcon Engineering Co
pdf (2140k) - Adcon Engineering Co
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
RRMICRO-SCREEN ® SystemsDIN Module <strong>Co</strong>ntrollersMICRO-SCREEN DIN Module <strong>Co</strong>ntrollers SpecificationsSystem Power RequirementsFuse RatingResponse Time24V dc ±15%, 10% maximum ripple, 1.5 amps max.2 amp, 250 V (3 AG or 5 x 20 mm slow blow)Light Screen: Less than 38 ms (all lengths)E-Stop: Less than 15 msStatus Indicators(on control box and receiver)Diagnostic Indicator<strong>Co</strong>ntrols and AdjustmentsEmergency Stop Switch InputRed = BLOCKED Flashing red = LOCKOUTGreen = CLEAR Flashing green = BLANKING ONYellow = RESET Double-flashing yellow = Waiting for Power-up Key ResetSingle-flashing yellow = ALIGNMENT. Flash rate increases with the number of sensing beams“made”, solid yellow when aligned and defined area is clear.Two-digit numeric display indicates cause of lockout condition and total number of beams blockedKeyed Reset of system lockout conditionsFloating Blanking selection switches and Fixed Blanking programming switchesAuto Power-up On-Off switchesEmergency Stop actuator must offer two normally closed contacts and be capable of switching 50 mA@ 30V dc. Total resistance limit of 30 Ω. Functional stop category 0 per NFPA 79 and ISO 13850(EN 418), Safety category 4 per iso 13849-1 (EN 954-1).Simultaneity requirement < 100 msOptical Safety SystemsAUX Non-safety Output <strong>Co</strong>ntactOutput <strong>Co</strong>nfiguration(FSD1, FSD2, and SSD)Enclosure<strong>Co</strong>nnectionsOperating <strong>Co</strong>nditionsReed relay; 125V ac or dc max., 500 mA max. (10 VA maximum, resistive load)Forced-guided contact relay (resistive load).FSD1 & 2, SSD = 250V ac max., 4 amp max.Mechanical life: 10,000,000 operations (minimum).Electrical life: 100,000 operations (typical @1.0 kVA switching power).Arc suppression is recommended when switching inductive loads. See Warning on page 319.Note: <strong>Co</strong>ntrollers with model suffix “2” have two FSD output contacts and those with model suffix “4”have four FSD output contacts.Size: See dimensions on next page.Material: gray polycarbonate, clear polycarbonate cover.Rating: NEMA 1, (IP 20)See pages 322 to 324 for general hookup information.Temperature: 0° to +50°C (+32° to 122°F)Relative humidity: 95% maximum (non-condensing)FMEA Tested Per requirements IEC 61496-1 (Type 4)Application NotesUse of fixed blanking requires sensors with 16 or more light beams. Up to 12 beams or 30% of thetotal number of beams in the array may be blanked, whichever is less. Call factory for applicationsassistance if a greater number of blanked beams is required.CertificationsIEC 61496-1 &2,Type 4Except USDINT-1T2EPresenceSensingDeviceBanner <strong>Engineering</strong> <strong>Co</strong>rp. • Minneapolis, MN U.S.A. • bannerengineering.com • Tel: 763.544.316487